Revised ASFP guidance sets out passive fire protection assessment changes

ASFP updates guidance for assessors

The Association for Specialist Fire Protection (ASFP) has revised its Guide to Passive Fire Protection for Fire Risk Assessors, with updates reflecting legislative and regulatory changes following the Grenfell Tower fire.

ASFP published the revised guide in an article dated 7 April 2026 by Niall Rowan, ASFP’s Technical and Regulatory Affairs Officer.

The guide was first published in 2012 after a certification body asked ASFP to produce simple passive fire protection guidance for fire risk assessors applying for certification under its scheme.

It was written for those carrying out Type 1 fire risk assessments and became one of the association’s largest publication downloads.

The revised version keeps the same three-part structure.

It includes a general and regulatory section, a methodology section covering different types of passive fire protection and annexes with further information, links to third-party guidance and an example checklist.

ASFP guide reflects legislative changes

Rowan wrote that the main changes in the revised guide arise from the Grenfell Tower fire on 14th July 2017 and the legislation that followed.

The Fire Safety Act 2021 (England & Wales) brought flat front doors into the scope of fire risk assessments under the Regulatory Reform (Fire Safety) Order 2005.

It also clarified that where a building contains two or more sets of domestic premises, the fire risk assessment should include an assessment of the building’s external wall system.

Recommendations from Phase 1 of the Grenfell Tower Public Inquiry led to the Fire Safety (England) Regulations 2022.

Those regulations mandated quarterly checks on fire doors in common parts of buildings and annual checks on flat front doors where possible, along with premises information boxes in blocks of flats containing building plans.

The Building Safety Act 2022 introduced a new regulatory regime for higher risk buildings, which the source material defines as buildings over 6 storeys and 18m high plus some other categories.

ASFP said these changes meant the revised guide now contains enhanced checks on fire doors, procedures for evaluating external walls and a new annex on external wall construction.

Type 1 assessments remain the main focus

The guide is aimed at fire risk assessors carrying out Type 1 fire risk assessments, described in the source material as the most common type for multi-occupied buildings.

These assessments focus on communal areas such as hallways, stairwells and escape routes and are non-destructive visual inspections.

The source material states that assessors are still expected to look above ceiling tiles on escape routes and above fire doors at corridor ends where they can.

Where significant passive fire protection shortfalls are identified, the guide recommends further inspection by specialists or a full invasive fire risk assessment such as a Type 2 or Type 4 assessment.

It also includes material on improving the competency of fire risk assessors and explains procedures used in undertaking assessment of external walls from the Fire Sector Confederation.

AEI Cables warns on cabling safety across electrical supply chain

AEI Cables commentary on cabling safety

AEI Cables has published commentary calling on the electrical supply chain to follow its duty of care on cabling safety during the current economic climate.

In its commentary, AEI Cables said specifiers, main contractors and installers are responsible for making sure cabling choices are relevant and safe for each application.

The company said Category 3 Control fire performance cables sit at the upper end of requirements.

These cables are designed to withstand heat and flames for up to 120 minutes.

AEI Cables said the cables support critical safety circuits in tall buildings, office spaces, hospitals, shopping malls and stadia.

The systems powered by these cables assist firefighting operations and support safe evacuation in life safety situations.

Fire performance requirements and standards

AEI Cables said recent legislation affecting electrical and fire safety includes the Building Safety Act 2022.

The Act sets new requirements for higher-risk buildings, defined here as those of at least 18 metres in height or at least seven storeys containing at least two residential units.

AEI Cables’ Firetec Enhanced cabling has been approved and certified by LPCB to BS8519 (Annex B), Category 3 Control as well as Category 2 Control.

Under BS8519, the code of practice contains six cable categories.

Three categories apply to power cables and three apply to control cables.

The categories cover survival times of 30, 60 or 120 minutes.

Dover sets out AEI Cables position

Stuart Dover, general manager of AEI Cables, said: “There are many challenges facing the electrical supply chain, not least the sheer amount of legislation and guidance being issued as well as tough trading conditions.

“At the same time, we must not forget our responsibilities to ensure the relevant cabling products and accessories are chosen for each project.

“Ultimately, we are talking about the safety of people moving about in large buildings.

“This goes beyond legislation.

“If in doubt, please seek guidance because the choice of cabling and level of fire performance is of paramount importance in the event of a fire.”

AEI Cables also said its products are supplied with approvals from independent bodies including BASEC and LPCB.

The company added that it holds approvals from organisations including Lloyds, the MoD and LUL, and works to international standards around the world.