Nittan fire detection system protects historic steam mill in Slovakia

Espat/Maxit Contracting has recently installed a Nittan Fire Detection System in a former steam mill building in Dolné Saliby, Slovakia, which was restored and preserved by the Trnava self-governing region.

The 100-year-old building is a crucial monument in the village and is now managed by the Heritage Museum in Galant, featuring an exhibition on the history of steam mills in the region and a depository for some of the museum’s collection of historic items.

The Nittan Evolution Series Detectors were primarily used for this project, including the Nittan EV-PYS Optical Detectors that come with a fully integrated sounder instead of a separate sounder base. These detectors are installed throughout the steam mill building to protect it from fire.

The sensor of the detector also drives and controls the EV-PYSVAD beacon base, and the entire Smoke/Sounder/Beacon assembly takes only one address for maximum system efficiency.

The installation of the Nittan Fire Detection System was conducted by Espat/Maxit Contracting. The systems is designed to provide quick and simple installation, saving time and money while remaining competitively priced. Additionally, it features a low profile and unobtrusive appearance.

For more information on the Nittan Fire Detection System and its installation, interested parties can contact Nittan by phone at 01483 769 555 or by email at sales@nittan.co.uk.

Ireland’s tallest commercial building installs Nittan fire detection system

Nittan Elite Partner, Fire Technology Ireland (FTI), has commissioned and supplied an L1 addressable fire detection system using Nittan Evolution fire detection devices at the tallest commercial building in Ireland, the EXO building in Dublin.

The EXO building contains 16 floors over three basements. More than 1,350 Nittan Evolution Analogue Addressable devices were installed as the primary detection system throughout the building, along with Advanced Electronics MxPro 5 Series fire alarm panels and network – one loop panel per floor for tenant space, two eight loop panels for landlord space and a four loop panel for the basement.

The use of Nittan EV-PYS combined smoke detector sounders reduced the overall visual impact on the floors and common areas. The units have a 360-degree viewing angle Omniview ring to allow for quick location and identification of any problem which may arise.

The use of Nittan Multiple Input Output units reduced installation time and the need to “hide” equipment. To provide a fault tolerant network, Evolution new ZMU2 complete with SCI were used for leak detection system in basements and top floor plant room with its own network.

Where it was necessary to mount wall units for signalling, EV-AV2 combined sounder strobes were used. These units have a profile of 30mm and are white in colour. The high visibility 360-degree strobe is extremely bright and visible from all angles. The 90 decibel sounder provides a clear audible tone which can be changed if required. A white cover neatly conceals the terminations and tone setting dip switches.

Evolution uses ASIC technology in the sensors and detection algorithms, combining extremely reliable fire detection together with a very high degree of protection against unwanted false alarms. Its highly flexible protocol allows for large amounts of information to be transmitted at high speed and is not affected by the number of devices on the loop.

David Browne from FTI commented: “The EXO is the largest commercial high rise building in Ireland, overshadowing the iconic Siptu building and Central Bank of Ireland which also have the same Nittan and Advanced systems installed by FTI. The EXO is installed with a complete open protocol, aesthetically pleasing choice of detection devices using Sine Wave Frequency Shift Keying transmission technology which is recognised as one of the most reliable and powerful Analogue Addressable systems on the market.

“The flexibility of loop sizes on Nittan protocol allows the setting of each floor to be configurable, enabling it to provide custom specifications for individual tenants. The protocol exclusively accepts 254 devices per loop, giving ample room for a sufficient number of additional devices.”