AEI Cables urges expert guidance on fire-safe cables amid market confusion

AEI Cables highlights confusion over new rules

AEI Cables has urged those responsible for specifying and procuring fire performance cables to seek expert technical advice amid what it describes as growing confusion around new legislation and compliance.

The company said many decision-makers in the supply chain are facing difficult choices about fire-safe products and may be unsure how to interpret current requirements.

AEI Cables stated that technical specialists within the company and within member organisations are available to support project teams who are uncertain about product selection.

Stuart Dover, General Manager of AEI Cables, said: “There seems to be a lot of confusion in the marketplace at the moment around new legislation which makes the selection of cables even more difficult.

“We are advising those who are faced with making these decisions to ask the experts.

“We have technical experts and there are industry specialists attached to member organisations.

“We would ask the decision-makers to seek another opinion if they are in any doubt because the effects of installing the wrong cables can be catastrophic.”

Fire performance cable categories and their uses

According to AEI Cables, clarity on the different fire performance categories is central to making appropriate choices for individual systems.

The company explained that Category 1 fire performance cables provide 30 minutes of fire resistance and are typically used for emergency lighting circuits.

Category 2 fire performance cables are described as offering 60 minutes of protection and are commonly installed for fire alarm systems.

For firefighting situations, AEI Cables noted that extended circuit integrity is required, with Category 3 fire performance cables specified to withstand exposure to fire for up to 120 minutes.

These higher-rated cables are used to maintain emergency power for critical safety circuits in tall buildings, office developments, hospitals, shopping centres and large venues such as stadia.

Category 3 control cables in life-safety systems

AEI Cables highlighted that the guidance for Category 3 Control fire performance cables covers a range of life-safety applications.

The company said these applications include evacuation alarms for disabled occupants in care homes, emergency voice communication systems and voice alarm systems in relevant buildings.

Systems supplied by these cables also power smoke and heat extraction installations, which support firefighting operations and help maintain conditions for safe evacuation.

AEI Cables added that the specified cable designs are intended to reduce harmful smoke, toxic gases and flame spread during a fire incident.

Firetec Enhanced and BS8519 compliance framework

AEI Cables reported that its Firetec Enhanced cabling range has been approved and certified by the Loss Prevention Certification Board (LPCB) to BS8519 Annex B as a Category 3 Control cable, as well as meeting Category 2 Control requirements.

The company said the British Standard Code of Practice BS8519 sets out six categories of cables, with three categories for power cables and three for control cables.

Each category in BS8519 is associated with a defined survival time of 30, 60 or 120 minutes, providing a framework for matching cable performance to the operational needs of different safety circuits.

How cable selection guidance affects building and safety projects

The information provided by AEI Cables is directly relevant for electrical contractors, system installers and fire-protection contractors who are tasked with choosing suitable fire performance cables for projects.

These groups often need to match cable survival times to specific systems such as emergency lighting, fire alarms and emergency voice communications, making the distinctions between Category 1, Category 2 and Category 3 products central to their work.

For fire engineering consultants, mechanical and electrical engineers and building services engineers, the clarification around BS8519 categories provides a reference point for design decisions on critical safety circuits in tall buildings, hospitals, office complexes, shopping centres and stadia.

Facility managers in these settings also rely on compliant cabling to keep evacuation alarms, emergency voice communication and smoke and heat extraction systems operational during a fire, which AEI Cables noted can affect firefighting and evacuation conditions over 30, 60 or 120 minutes.

By drawing attention to available technical support, AEI Cables has indicated that specifiers and decision-makers who are uncertain about new legislation or about how to apply cable categories can obtain additional guidance before making purchasing decisions.

Fire safety cable standards drive demand for Category 3 Control in UK

Updated guidance prompts cable safety focus

AEI Cables has reported increased demand for Category 3 Control fire performance cables in the UK, following renewed attention to guidance in BS 8519:2020.

The British Standard outlines how control cables should be selected and installed in fire safety systems used in buildings such as care homes, offices, hospitals and shopping centres.

The company said these systems include evacuation alarms for disabled occupants, emergency voice communication systems and voice alarms in public buildings.

The guidance sets expectations for cable performance during fire-related emergencies and categorises cables by their survival time and function.

According to AEI Cables, following – and exceeding – these minimum standards improves the reliability of critical fire safety systems.

AEI Cables comments on current UK trends

Stuart Dover, General Manager of AEI Cables, said the company is seeing a steady rise in customer interest for Category 3 Control cable types.

He said: “We are seeing quite an increase in demand for Category 3 Control cables and we can only stress that if they meet and exceed all standards requirements this can only help in the interest of safety of property and lives in these critical spaces.

“Meeting standards is a minimum requirement but going above and beyond these standards will help firefighters in a real-life fire situation.”

AEI Cables has been promoting the role of LPCB-certified products and urging the industry to take account of updated codes of practice.

According to Dover, the cables play a role in powering systems like smoke control, heat extraction and evacuation alarms, which are relied upon during incidents requiring fire service intervention.

Firetec Enhanced and BS 8519 Category 3 Control

The company said its Firetec Enhanced cabling has received third-party certification from LPCB.

This certification applies to BS 8519 Annex B under both Category 2 Control and Category 3 Control classifications.

The BS 8519 Code of Practice includes three power cable categories and three control cable categories.

Each category aligns with survival times of 30, 60 or 120 minutes depending on the intended system function during a fire.

AEI Cables said the updated code provides clarity for contractors, developers and consultants specifying products for life safety systems.

Industry approvals and UK use cases

AEI Cables stated that its fire performance cable range is backed by third-party testing and certification from organisations including BASEC and LPCB.

The manufacturer added that it also holds approvals from Lloyds Register, the Ministry of Defence, Network Rail and London Underground.

Its cables are designed and tested to international standards and are supplied to infrastructure, defence and public sector projects.

The company said the most common UK applications include use in tall buildings, healthcare environments and transport hubs where system failure poses a life safety risk.

Role of Category 3 Control cables in emergencies

Control cables serve different functions from power cables, and Category 3 Control cables are specified for the highest level of system resilience.

These cables are used in systems that support evacuation, suppress smoke and allow fire services to manage internal conditions during an emergency.

According to AEI Cables, these systems must remain operational during extended fire exposure.

The company said reducing toxic gas and flame spread also assists in safer evacuation routes and fire service access.

AEI Cables has urged those responsible for design and specification to prioritise cables with enhanced survivability and independent certification.

Fire safety cable standards drive demand for Category 3 Control in UK: Summary

AEI Cables has reported growing demand for Category 3 Control fire safety cables.

The company attributed this trend to the updated BS 8519:2020 guidance.

This British Standard outlines cable selection for life safety systems.

Category 3 Control cables are used in evacuation and fire management systems.

AEI Cables said meeting and exceeding standards improves fire safety.

Firetec Enhanced cables have been certified by LPCB to BS 8519.

BS 8519 includes six cable categories based on function and duration.

AEI Cables holds certifications from BASEC, LPCB and others.

Its cables are used in care homes, hospitals and high-rise buildings.

Increased UK demand for Category 3 Control fire performance cables

Tougher UK legislation linked to rising cable demand

AEI Cables has reported an increase in demand for Category 3 Control fire performance cables following recent changes to legislation in the United Kingdom.

According to the company, meeting this demand requires effective coordination between manufacturers and distributors.

AEI Cables explained that these cables are critical for powering safety systems such as smoke and heat extraction, which support firefighting operations and occupant evacuation.

AEI Cables calls for industry-wide coordination

Stuart Dover, general manager at AEI Cables, said: “We have seen a rise in the demand for these cables but working together with our distributors we are satisfying our customer needs.

“Together, we can meet the increase in requirements which ultimately make sense for the safety of people and property.

“We offer a comprehensive range of Category 3 Control backed up with our technical support and guidance for these specific uses.”

The company noted that guidance applies to systems including evacuation alarms for disabled residents in care homes, emergency voice communications and voice alarm systems across a range of public and commercial buildings.

These include high-rise buildings, office facilities, hospitals, shopping centres and stadiums.

Standards compliance emphasised under BS8519

AEI Cables stated that it has been promoting the revised Code of Practice under British Standard BS8519:2020 for the selection and installation of Category 3 Control fire performance cables.

It said the revised guidance is designed to reduce the release of harmful smoke, toxic gases and the spread of flame during a fire.

The company noted that its Firetec Enhanced cables are approved and certified by LPCB for both Category 2 and Category 3 Control under BS8519 Annex B.

BS8519 outlines six categories of fire-resistant cables, with three relating to power cables and three to control cables.

Each of the six categories corresponds to a survival time of either 30, 60 or 120 minutes.

AEI Cables supplies certified products to UK and international standards

AEI Cables confirmed that its products are approved by independent bodies including BASEC and LPCB.

The company also holds approvals from the Ministry of Defence, Network Rail, Lloyd’s Register and London Underground.

It added that it manufactures in line with international specifications for supply globally.

Increased UK demand for Category 3 Control fire performance cables: Summary

AEI Cables has reported increased demand for Category 3 Control fire performance cables in the UK.

The company attributed the rise to tougher legislation related to life safety systems.

It stated that collaboration between manufacturers and distributors is essential to meet customer requirements.

AEI Cables said the cables are used in critical systems such as smoke extraction and emergency alarms.

General manager Stuart Dover said the company is meeting this demand in partnership with its distributors.

The company highlighted that BS8519:2020 provides the relevant Code of Practice.

Firetec Enhanced cabling is certified by LPCB for Category 2 and Category 3 Control applications.

BS8519 includes six cable categories based on power or control use and survival time.

AEI Cables products are independently certified by BASEC and LPCB.

It also holds UK-based approvals from bodies including Network Rail and London Underground.

AEI Cables manufactures to international standards for global supply.

AEI Cables calls for Building Safety Act to be widely understood

AEI Cables has said the performance of cabling in critical fire safety systems needs to be clearly understood as part of the new Building Safety Act.

The new Building Safety Act makes requirements for higher-risk buildings which are those deemed to be of at least 18 metres in height or at least seven storeys containing at least two residential units.

The Act updates guidelines for construction and management of higher risk buildings and covers the whole supply chain including electrical safety systems and cabling. The current British Standard Code of Practice BS 8519 identifies six categories of power and control cables with survival times of 30, 60 or 120 minutes. 

General Manager, AEI Cables, Stuart Dover’s statement

Stuart Dover, General Manager of AEI Cables, said: “There is a lot of new detail in the legislation and we welcome the requirements of the Act. However, there is a pressing need to understand the part played by electrical safety systems and the cabling that operates these systems.

“There is good information available through the cabling industry including our own technical advisers about cable testing, cable classifications and cable performance in real fire conditions.”

The systems in these buildings powered by electrical cables, including smoke and heat extraction systems, assist fire services in firefighting and a safe evacuation in the case of life safety.

The Building Safety Regulator

The Building Safety Regulator will oversee the safety and performance of all buildings, as well as having a special focus on high-rise buildings. It will promote competence and organisational capability within the sector including for building control professionals and tradespeople.

Building owners should now have their building safety regime in place and any occupied higher-risk buildings should be registered with the Building Safety Regulator.

New legislation needs to be welcomed, says AEI Cables: Summary

AEI Cables has called for the updates to the Building Safety Act to be widely understood. AEI’S General Manager said that there is a pressing need to understand the part played by electrical safety systems and the cabling that operates these systems.