Latest Fire Door Regulations: A Global Perspective for UK and US Safety Leaders

Ask a facilities manager what keeps them up at night, and fire doors probably won’t be the first thing out of their mouth. Budgets, staffing, and a leaking roof, maybe. But spend enough time around fire investigators and building safety lawyers, and you start to hear the same uncomfortable truth repeated: fire doors are where compliance quietly falls apart. Not because people don’t care. Usually because nobody’s been watching closely enough. That’s changing now, and it’s changing fast. 

Fire door regulations in both the UK and the US have been tightened significantly over the past few years, and the pressure isn’t letting up. What used to be a box-ticking exercise buried in a building’s safety file is now a named legal duty, with inspection records, deadlines, and real consequences for getting it wrong. This piece looks at where things currently stand across both countries, and with one eye on the wider global picture. If you’re responsible for occupied buildings in any capacity, there’s a lot here worth your attention.

Why Fire Door Regulations Are Becoming a Global Priority

The honest answer involves Grenfell. The 2017 fire in North Kensington killed 72 people and cracked open every assumption the UK building sector had about passive fire protection systems being “good enough.” Fire door failures, propped open, incorrectly fitted, and missing seals were part of a much larger systemic failure. But they were there. Other countries were already watching. Australia, Canada, and parts of the EU have all been tightening fire door compliance standards in the years since. 

It’s not exactly copycat legislation, but there’s a clear convergence around what good looks like. Testing regimes, inspection frequencies, and third-party certification requirements are all trending toward stricter requirements. Understanding how fire safety standards connect across jurisdictions matters more than many safety leaders realize, especially if you’re managing properties in multiple countries.

How UK Fire Door Rules Are Reshaping Building Safety

Two pieces of legislation changed everything for UK building owners. The Building Safety Act 2022 and the Fire Safety (England) Regulations 2022, between them, created a compliance regime that’s noticeably harder to ignore than the one that came before. The headline requirement most people know is that responsible persons in multi-occupied residential buildings over 11 meters now have to check communal fire doors every three months. Individual flat entrance doors every year. That’s not guidance. That’s a legal obligation, with documentation expected.

The more important shift is about what “compliant” actually means now. The regulations don’t just ask whether there’s a fire door present. They ask whether the whole assembly is correct: frame, door leaf, intumescent seals, hardware, glazing, self-closing mechanism. All of it together.  The knock-on effects for procurement and construction are real too. As we’ve covered in our look at construction compliance risk, specifiers and contractors are having to think about certification from the start of a project, not as an afterthought at handover.

Understanding US Fire Door Standards for Commercial Facilities

In the US, the regulatory framework differs in structure but is similar in intent. NFPA 80, the Standard for Fire Doors and Other Opening Protectives, is the central reference point for commercial fire door requirements. It mandates annual inspection and testing of fire door assemblies in commercial buildings, carried out by someone who actually knows what they’re looking at. 

Under NFPA 80, fire door regulations aren’t satisfied by a compliant door leaf installed in a non-compliant frame or fitted with hardware not part of the original listing. NFPA 101, the Life Safety Code, works alongside NFPA 80 to define where fire doors are actually required, based on occupancy type. Worth reading alongside this: the product safety rules in UK context, which shows how two English-speaking countries can approach the same safety problem in quite different ways and still reach broadly comparable outcomes.

Role of Certified Fire-Rated Doors in Risk Reduction

A fire-rated door system isn’t just a heavier door. It’s an assembly that’s been subjected to controlled fire conditions to prove it holds for a defined period: 20, 45, 60, or 90 minutes, depending on where it sits in a building and what it’s there to protect. Third-party certification is what makes that claim credible rather than just a marketing statement.

In the UK, schemes such as Certifire and BM TRADA assess whether door assemblies meet the required standards under test conditions. In the US, UL and Intertek do equivalent work. The certification applies to the whole assembly as tested, not to components selected individually and combined in the field. This is where many building owners get caught out. They buy certified doors. 

They think they’ve handled it. But certification only holds when the door is installed exactly as it was tested: the same frame specification, the same hardware, the same fixings. Deviate from that, and you’ve bought the appearance of compliance without the substance of it. The practical risk reduction delivered by properly specified certified fire door assemblies isn’t theoretical. Fire investigation reports reference the performance of fire doors. 

Doors that held. Doors that didn’t. The link between correct specification and actual performance in a real fire is well documented, and so is the inverse. There’s also the insurance and liability angle, which doesn’t get discussed as often as it should. An incorrectly installed or uncertified door isn’t just a safety risk. It’s a financial one. Policies can be invalidated. In cases involving fatalities, the legal exposure for building owners and responsible persons is significant and getting harder to avoid.

Why Fire Door Inspection and Maintenance Matter

Here’s the version of this that nobody puts in the press release: the most common fire door failures found during inspections aren’t exotic. They’re a door wedged open with a fire extinguisher. A self-closer that’s been disconnected because a resident found it annoying. A seal that’s been painted over during a refurbishment and no longer does anything. A gap at the bottom is three times wider than it should be. Fire door inspection protocols exist precisely because buildings change over time. 

Doors get used thousands of times a year. Seals degrade. Hinges wear. Frames shift slightly with seasonal movement in a building’s structure. The door that was correctly installed and performing well at handover may not be the same door five years later without active maintenance. Under current fire door regulations in both countries, inspection is mandatory. In the UK, frequencies are set out in legislation. In the US, NFPA 80 mandates annual commercial inspections. 

Both frameworks require records of who inspected, what was found, what was fixed, and when. That audit trail is what a regulator or insurer asks for after an incident. What inspectors actually check covers a lot of ground: gap tolerances around all four sides of the door; seal condition and continuity; whether the self-closer brings the door fully home; latch engagement; condition of glazing, signage, and the frame itself. Digital inspection tools have made this easier to evidence and harder to quietly overlook. 

Paper checklists in a folder are being replaced by time-stamped mobile records with photographs linked to specific door references. Maintenance matters equally. When a component fails, it needs to be replaced with like-for-like manufacturer-approved parts, matched to the original certified assembly. Fitting any available closet because it’s roughly the right size isn’t compliant. Field observations recorded in fire protection observations show propped doors and degraded seals consistently at the top of the deficiency list, year after year.

How Smart Technologies Are Changing Fire Door Safety

Sensor technology embedded in fire door assemblies is commercially available now and being deployed at scale in larger estates. These systems monitor door status continuously, whether it’s open or closed, how long it’s been open, whether the gap is within tolerance, and whether the closer is actually working. Alerts go straight to facilities management when something’s wrong, without waiting for the next scheduled inspection. 

The intersection with AI in emergency response is worth following. Predictive maintenance tools that learn from sensor data across a portfolio of doors can flag assemblies showing early signs of wear before they actually fail an inspection. That’s a move from reacting to problems to catching them before they become problems. In large high-rise fire protection contexts, that early warning has real operational value.

Integration matters too. Smart fire door systems can integrate with smoke detection and building evacuation management, releasing hold-open devices and automatically closing fire doors on a floor or across the entire building when an alarm is activated. That’s not a theoretical future capability; it’s working now in hospitals, airports, and large commercial sites.

For compliance recording, digital inspection apps have transformed day-to-day workflows. GPS-stamped records, photographs tied to specific door references in an asset register, automatic scheduling, centralized dashboards showing compliance status across an entire portfolio. For a safety manager responsible for multiple sites, that level of visibility isn’t just convenient; it’s the only realistic way to manage the load.

Challenges in Managing Multi-Site Fire Door Compliance

If you’re managing fire door compliance across a single well-documented building, it’s hard work but manageable. Scale that to 20 sites, or to sites across both the UK and the US, and the difficulty multiplies quickly. Fire door regulations aren’t uniform. NFPA 80 and the Fire Safety (England) Regulations 2022 share the same underlying intent but differ on specifics: inspection frequencies, certification pathways, and what qualifies as a competent inspector. In the US, state and local AHJ interpretations add another layer. A compliance program that works well in one city may need adjustment for another. 

That inconsistency creates a real administrative burden for multi-site operators. Asset management is foundational. You need an accurate register of every fire door assembly across a portfolio, including ratings, original certification details, installation dates, inspection histories, and component replacements. Without that baseline, building safety compliance becomes guesswork. Many organizations don’t have it, which is a major reason multi-site fire door compliance remains a persistent gap. Parts sourcing creates its own headaches. 

Commercial fire door requirements specify that replacement components match the original certified assembly. When a manufacturer has ceased trading or a product line has been discontinued, finding a compliant replacement that preserves the assembly’s certification requires real effort. The temptation to use whatever’s available and roughly the right size is understandable and non-compliant. Training is the third element that gets squeezed when resources are tight. UK legislation leans heavily on the “competent person” concept, someone with actual demonstrated knowledge, not just a willing volunteer. 

NFPA 80 similarly expects inspectors to have a genuine understanding of the standards they’re applying. That doesn’t come from a one-hour induction. Organizations need proper, ongoing training programs and to update them as fire door regulations change. 

The direction of travel is clear enough, even if the path is messy: requirements are getting stricter, the documentation burden is increasing, and the consequences of getting it wrong are harder to absorb. Safety leaders who treat this as an administrative task rather than a genuine operational priority tend to find out the hard way why that distinction matters.

Conclusion

There’s a version of this topic that gets filed under regulatory housekeeping. It shouldn’t be. Fire door regulations exist because buildings have killed people when their passive fire protection systems failed, and fire doors were part of that failure. The rules that followed in the UK, especially, but in the US too, reflect hard lessons learned at real cost. 

The practical ask isn’t complicated, even if the execution takes sustained effort: buy certified products, install them correctly, maintain them properly, inspect them on schedule, and keep records you could defend in a coroner’s court. Smart technology is making parts of that easier. It doesn’t replace people who understand what they’re responsible for and take it seriously.

Frequently Asked Questions

What are the latest fire door regulations in the UK and the US?

In the UK, the Fire Safety (England) Regulations 2022 and the Building Safety Act 2022 set out the current framework. Responsible persons in qualifying high-rise residential buildings must check communal fire doors every three months and flat entrance doors once a year. 

Why are fire door inspections important for commercial buildings?

Fire door inspection protocols catch what quietly goes wrong: seals that have worn or been painted over, closers that were removed, hinges that have shifted, gaps that have grown beyond the allowed tolerance.

How often should fire doors be inspected and maintained?

Under UK fire door regulations, responsible persons in qualifying high-rise residential buildings must inspect communal fire doors quarterly and flat entrance doors annually. 

How do certified fire-rated doors improve building safety?

A certified fire door assembly has been independently tested as a complete unit to confirm it contains fire and smoke for a specified period.

What are the risks of non-compliance with fire door regulations?

The most serious risk is the one that matters most: a door that fails during a fire, allowing smoke and flames to move through a building faster than they otherwise would.

National fire safety consistency questioned following latest CE Safety data

Regional disparities in CE Safety fire inspection data

New research reveals that 19 fire and rescue service areas in the UK experienced a decline in satisfactory fire safety inspection outcomes over the last three financial years.

Fire safety specialists CE Safety analysed the percentage of satisfactory audits conducted by fire and rescue services between 2022/23 and 2024/25.

The data shows that 25 regions recorded an increase in satisfactory ratings during the same period.

Humberside recorded the largest decline in satisfactory audit outcomes.

In the 2022/23 period Humberside reported an 84% satisfactory rate.

This figure fell to 20% in 2023/24 and reached 8% in 2024/25.

Buckinghamshire saw a 43% drop in satisfactory audits between 2023/24 and 2024/25.

The satisfactory rate in Buckinghamshire moved from 75% in 2022/23 to 49% in 2023/24 and 28% in 2024/25.

Surrey experienced a 26.6% decline over the last financial year.

Northumberland recorded a similar decrease of 26.3% in satisfactory audit rates.

Other areas with falling rates included Dorset and Wiltshire at 34% and West Sussex at 34%.

Cumbria recorded a 39% satisfactory rate following an 18.75% decline.

Improving fire safety standards and regional leaders

Hertfordshire recorded the highest increase in satisfactory inspections moving into the 2024/25 financial year.

The satisfactory rate in Hertfordshire rose from 52% in 2023/24 to 89% in 2024/25.

North Yorkshire saw satisfactory audits increase by 32.3% to reach a rate of 82%.

Cleveland reported a 26.1% increase in its satisfactory inspection rate.

Cheshire maintained the highest overall percentage of satisfactory inspections at 92%.

Gary Ellis, managing director of CE Safety, commented on the findings.

Ellis said: “If you own a building or workplace in England or the UK, there are strict measures in place you must abide by, from appointing a fire marshal to having the correct fire doors installed, to keeping updated risk assessments to thorough fire prevention efforts, including working fire alarm systems.

“The importance of ensuring audits take place in buildings across the country cannot be understated – there are still thousands of fires in workplaces and public buildings in the UK every year.

“This is an area I hope to see improve radically in the near future, however building managers and owners should not wait until they are penalised before they act when it comes to fire safety.

“The responsibility is yours and should be treated with the utmost importance.”

The data highlights a lack of consistency in building safety standards across the country.

BSI report sets out UK fire safety standards work for 2024–2027

Fire safety standards programme report details revisions, plans and committee role

The British Standards Institution has published its first annual overview of how the UK’s fire safety standards programme is being run, what changed in 2024–2025 and what is coming next in 2026–2027.

The document was launched at BSI’s Annual Fire Safety Conference on 29 January 2026. It comes from the Fire and Built Environment Sector Policy and Strategy Committee, known as FSH/0, which sits at the top of BSI’s fire safety standards structure for the built environment.

Rather than being a technical standard itself, the report functions as a map of the standards system. It explains who is involved, how priorities are set, which standards have recently been updated and which major projects are in the pipeline.

BSI frames this annual publication as part of a push for greater transparency, making standards work easier to understand and follow beyond the relatively small circle of people directly involved in committees.

Who FSH/0 is and why it matters

FSH/0 operates at the highest tier of the national standards framework for fire safety. Its remit covers the full life of a building, from design and construction through occupation, management, maintenance and eventual end of life.

In practical terms, this means it looks across everything that touches fire safety in buildings, including fire precautions, fire protection systems and the infrastructure that supports safe evacuation and firefighting.

The committee performs four main roles.

First, it sets strategic priorities for developing new standards and revising existing ones, deciding where effort should be focused.

Second, it carries out horizon scanning, looking ahead at emerging risks that could shape future standards. The report gives examples such as lithium-ion battery fires, new energy systems, increased automation, digital building systems, new construction materials and modern methods of construction.

Third, it coordinates specialist technical committees to reduce duplication and keep different strands of standards work aligned.

Fourth, it provides a national forum where regulators, fire and rescue services, manufacturers, installers, consultants, building owners, academics and professional bodies can contribute to standards development.

In effect, FSH/0 sits between government policy, industry practice and the detailed technical work of standards committees.

Leadership, structure and how the system is organised

FSH/0 is chaired by Aman Sharma MBE. Under his leadership, the report highlights a focus on strengthening the overall standards infrastructure and widening participation, including bringing in early-career professionals and people with expertise in digital and emerging technologies.

The committee oversees around two dozen specialist technical committees. The report names several key examples, including committees covering fire detection and alarms, fire precautions in buildings, hazards to life from fire and fixed firefighting systems.

It also maintains formal links with committees working on related areas such as construction design, digital modelling, accessibility, lifts, furniture flammability, personal protective equipment and explosion safety. FSH/0 works closely with CB/0, BSI’s broader built environment committee.

Day-to-day coordination is supported by a dedicated BSI Standards Committee Manager, and FSH/0 typically meets several times a year to review progress, approve new projects and respond to emerging issues.

Who was around the table in 2024–2025

The report sets out who was represented on FSH/0 during 2024–2025, giving a sense of how broad the committee’s membership is.

Members included the Association for Specialist Fire Protection (ASFP), Euralarm, the Fire Industry Association (FIA), the Health and Safety Executive (HSE), the Institution of Fire Engineers (IFE), the National Fire Chiefs Council (NFCC), Northern Ireland Building Regulations, the Office for Product Safety and Standards (OPSS), the Scottish Fire and Rescue Service and the Scottish Government.

BSI notes that this mix covers fire engineering, manufacturing, installation, maintenance, building design, risk assessment, construction, enforcement and regulatory policy, rather than being dominated by any single perspective.

How the work connects to Grenfell Tower Inquiry Phase 2

A significant strand of recent standards activity is explicitly framed as aligning with recommendations from Phase 2 of the Grenfell Tower Inquiry.

One of the clearest examples is BS 8674:2025, which sets out a framework for the competence of individual fire risk assessors. The report links this to recommendations around clearer competence standards and potential future mandatory accreditation.

The report also highlights work on an amendment to BS 750, the standard for underground fire hydrants. This is described as a direct response to Inquiry Recommendation 40, and aims to clarify when and how flow coefficients should be measured.

More broadly, BSI describes ongoing engagement with government and industry to keep standards aligned with evolving policy in the post-Grenfell landscape.

Relationship with the Building Safety Act and Fire Safety Act

BSI states that its standards work in 2024–2025 has been closely aligned with both the Building Safety Act 2022 and the Fire Safety Act 2021.

The report groups several key documents within this framework: BS 8674:2025 on fire risk assessor competence, BS 9792:2025 on fire risk assessment for housing, PAS 79-1 on non-housing fire risk assessment and PAS 9980 on fire risk appraisal of external walls.

These are presented as tools that support accountable persons, responsible persons and dutyholders in meeting their legal responsibilities.

How BSI has supported understanding and implementation

Beyond writing standards, the report describes a range of activity aimed at helping the sector understand and use them.

BSI Knowledge has published explanatory articles on standards such as BS 9991, BS 8674, BS 5839-1 and BS 5266-1.

The organisation has also run sector briefings and events on topics including construction product regulation, competence and legislative change.

There has been collaboration with bodies such as the Institution of Fire Engineers and the Fire Sector Confederation, particularly around BS 8674.

On PAS 9980, BSI continues to support its use within government remediation frameworks and Building Safety Fund guidance. A structured revision programme began in 2024, with main consultation taking place in 2025.

BSI also runs an Education Hub aimed at educators, researchers and practitioners who want to engage more closely with standardisation.

What actually changed in 2024–2025

Several major standards were revised or published during this period.

BS 9991:2024, the main residential fire safety standard, underwent a substantial update. Its scope was expanded to cover residential care homes. Provisions on sprinklers were updated, including for single-stair buildings and height thresholds. The standard adopted European fire-resistance classifications for doors and strengthened guidance on smoke control and evacuation lifts in taller buildings.

BS 9792:2025 set out a clearer framework for fire risk assessment in housing, including a nine-step methodology and guidance for assisted living and supported housing. It is designed to sit alongside PAS 79-1 and PAS 9980 as part of a national approach to risk assessment across different building types.

BS 8674:2025 introduced three competence levels for fire risk assessors: Foundation, Intermediate and Advanced. It covers not only technical knowledge but also skills, behaviours, ethics, supervision and continuing professional development, and is linked to future plans for mandatory accreditation under the Building Safety Act.

BS 5839-1:2025, covering fire detection and alarm systems in non-domestic buildings, added a new section on system modifications, tightened controls on acceptable variations, updated guidance on manual call points and clarified expectations for automatic detection in sleeping-risk areas.

BS 5266-1:2025, the emergency lighting standard, expanded its scope to cover emergency escape lighting, standby lighting and local-area emergency lighting, placed greater emphasis on lighting uniformity and aligned more closely with European standards EN 1838 and EN 50172.

PAS 9980 was under revision during this period, with consultation completed in 2025 and publication expected in Q2 2026. Together with PAS 79-1 and BS 9792, it forms a cross-building-type framework for fire risk assessment and appraisal.

What is coming in 2026–2027

The report sets out a substantial forward programme of work.

BS 9994 is planned as a new specification for creating, documenting and managing fire strategies throughout a building’s lifecycle. It is intended to standardise structure, terminology and review processes, replacing and expanding on PAS 911. Public consultation is expected in Q1–Q2 2026, with publication likely in late 2026 or early 2027.

BS 9996 will cover the commissioning and maintenance of integrated fire safety systems, including alarms, suppression, smoke control, evacuation lifts and cause-and-effect logic. The aim is to ensure that changes to systems do not undermine the original fire strategy. A Draft for Public Comment is expected in Q2–Q3 2026, with publication in 2027.

The revised PAS 9980 is due for publication in Q2 2026, with clearer decision pathways, terminology and alignment with the wider BS 999X family of standards.

PAS 9970-1 and PAS 9970-2 will address fire safety during construction. The first covers organisational and site fire safety, while the second deals with temporary fire detection and alarm systems on construction sites. Consultation is expected in Q1 2026 and publication in Q4 2026.

A revision of BS 9990, covering non-automatic firefighting systems such as wet and dry risers and firefighting mains, is expected to go to consultation in Q3–Q4 2026, with publication in 2027.

An amendment to BS 750 on underground fire hydrants is planned for consultation in 2026, again responding to Grenfell Inquiry Recommendation 40.

Finally, BS 9999, the main non-domestic fire safety standard, is scheduled for a major update with consultation in Q2–Q3 2027 and publication in 2028. The revision is intended to align with post-Grenfell reforms and with BS 9991, BS 9994 and BS 9996, covering issues such as fire strategies, evacuation planning, dutyholder responsibilities and digital records.

How people can get involved

The report emphasises that standards development depends on broad participation rather than being driven solely by BSI.

Individuals and organisations can apply or be nominated to join technical committees, serve on drafting panels for specific standards and respond to Drafts for Public Comment via the Standards Development Portal.

Contributions can also be made through professional bodies such as the Institution of Fire Engineers, the Fire Industry Association, the Association for Specialist Fire Protection and BAFSA.

BSI also invites evidence or case studies to support FSH/0’s horizon-scanning work, alongside engagement through consultations, calls for evidence, conferences and roundtables.

What the report presents FSH/0 as doing

Overall, the report positions FSH/0 as the central coordinating body for UK fire safety standards, increasingly transparent through the publication of this annual overview, closely aligned with post-Grenfell reforms and actively managing a wide programme of revisions, new standards and PAS projects across 2026–2027.

It presents this work as part of maintaining a coherent, nationally consistent fire safety standards framework for the built environment.

Jim Pauley announces NFPA LiNK 3.0 update during Intersec NFPA Day

NFPA LiNK 3.0 announced at Intersec Dubai 2026

NFPA LiNK 3.0 was announced at Intersec Dubai 2026 in Dubai, United Arab Emirates, on 13 January 2026.

The update was confirmed by the National Fire Protection Association (NFPA) following its participation in the event, where it hosted an NFPA Day programme for government and industry representatives.

The announcement was made by NFPA President and CEO Jim Pauley as part of the programme, which focused on fire, life and electrical safety issues in the region.

The updated version of NFPA LiNK is positioned as a new generation of the organisation’s digital platform for delivering its codes, standards and related resources.

The platform is designed to support faster decision-making when applying NFPA’s library of more than 300 codes and standards.

Pauley said: “We couldn’t be prouder to launch the new AI-powered enhancements in NFPA LiNK with CASI here at Intersec Dubai during NFPA Day.

“This new version is a game-changer that takes NFPA LiNK from being a reference tool to a career companion for professionals across the world.

“It brings intelligence, accessibility, and speed to finding the latest codes and standards, helping people apply safety more effectively wherever they are.

“And with the inclusion of CASI, our new AI-powered assistant, users can trust the information they are getting, because it’s grounded in official NFPA information and resources that define safety.

“Our participation in Intersec Dubai 2026 and the launch of this new version of NFPA LiNK bolsters our dedication to helping raise the bar for fire, life, and electrical safety across the region,” Pauley said.

What NFPA LiNK 3.0 includes

NFPA LiNK is a subscription-based platform that provides access to more than 300 NFPA codes and standards.

The latest version introduces new digital tools intended to support more structured and collaborative ways of working.

Key additions include an AI-powered assistant called CASI (Codes and Standards Intelligence), interactive and customisable notebooks and a redesigned dashboard.

CASI enables users to hold interactive conversations, receive summarised responses, access citations from NFPA content and retain complete chat histories while reviewing the relevant material.

The notebook function allows users to import images, insert code references, add text, create checklists and manage project-related work within the platform.

Eng. Dana Kamal, NFPA MENA director of International Business Development, said: “The introduction of the latest version of NFPA LiNK at Intersec Dubai reflects our commitment to delivering innovation where it matters most – directly to practitioners in the environments where they operate, whether on job sites, in control rooms, or training facilities, and throughout the lifecycle of complex projects.

“This region is setting the pace for safety and technology, especially when it comes to integrating AI.

“With tools like NFPA LiNK’s interactive notebooks, and CASI, we’re delivering what our colleagues around the world have asked for; smarter workflows, faster answers, and content that they can trust, delivered where and when they need it,” Kamal added.

NFPA Day sessions and regional engagement

NFPA’s presence at Intersec Dubai 2026 included sessions examining AI in inspection practices, fire protection approaches for giga-projects and the region’s energy and infrastructure priorities.

The programme also supported engagement with regional stakeholders, including government authorities, industry leaders and technical experts.

The event activity and the launch of NFPA LiNK 3.0 were presented as part of NFPA’s wider work across standards development, enforcement, education and public engagement.

FPA and FDM partnership to deliver advanced fire safety standards across UK facilities

FPA and FDM partner on fire safety standards

The Fire Protection Association (FPA) has announced a new partnership with FDM to provide fire safety training courses and qualification pathways across their UK sites.

The collaboration follows the FPA’s earlier announcement of its new Training and Education Centre (TEC) in Oxfordshire, which is set to open in January 2026.

According to the FPA, the TEC will offer learners an authentic and practical training environment supported by several industry partners, including FDM.

The organisation said that through this agreement, FPA learners will soon be able to complete FDM courses at the new site.

Partnership expands course availability and accreditation

FDM, which was named Training Provider of the Year at the 2025 Fire & Security Matters Awards, will provide several of its specialist courses at the TEC.

These include its Fire Door Installation and Fire Door Repair and Maintenance courses, along with the Fire Door Procurement training course and the Level 3 Diploma Qualification in Inspection of Fire Resistant Doorsets.

The FPA confirmed that these will be delivered under licence at the new facility.

Additionally, the collaboration will allow the FPA to deliver its Fire Risk Assessor qualifications at FDM’s training centre in Bury, Greater Manchester.

Shared commitment to raising fire safety standards

Nicola John, Managing Director of FDM, said: “We’re extremely proud that the FPA, one of the industry’s most well-established and respected associations, has recognised that our courses and materials are industry leading.

“We share a dedication to raising fire safety standards, and this collaboration is just the start of a long and prosperous partnership.

“Together, we’ll bridge knowledge gaps for its thousands of members across the UK and shape the future of fire safety in our industry.”

Kelly Donoghue, Head of Training at the FPA, said: “Our partnership with FDM further strengthens our comprehensive range of fire door training and complements our wider suite of fire safety training courses and qualifications which we deliver to support professionals with their ongoing competence.

“This collaboration reflects our shared commitment to improvement for the industry, using our joint expertise to raise fire safety standards and educate and upskill fire and construction professionals.”