Heritage fire safety upgrades continue across priority sites in Japan

Fire safety programme continues at heritage sites

Japan is continuing fire protection upgrades at priority heritage sites after the 2019 blaze that destroyed major structures at Shuri Castle in Okinawa.

The South China Morning Post reported that work has not yet begun at around 30 per cent of the 107 cultural properties placed under a national programme launched in 2020 by the Agency for Cultural Affairs.

So far, 64 designated sites have installed new fire protection measures.

A further seven locations are undergoing upgrades.

The programme was introduced after the October 2019 fire at the UNESCO World Heritage site in Naha, which burned for nearly 12 hours and destroyed six buildings covering about 4,200 square metres.

Investigators later found that the fire began at an electrical distribution board.

Authorities ruled out arson.

According to Hiroko Moriyama of the Agency for Cultural Affairs, the programme adds measures beyond those required under Japan’s Fire Service Act.

World Heritage sites and national treasures are being equipped with flame detectors, specialised fire hydrants and upgraded alarm systems alongside conventional extinguishers.

Moriyama said: “This will help safeguard irreplaceable cultural assets that would otherwise be lost forever if they were damaged by fire.”

Funding, delays and the revised timetable

The South China Morning Post also reported that the Japanese government will cover up to 85 per cent of the cost of the new fire protection systems.

Nearly 13 billion yen, equivalent to around US$82.3 million, has already been allocated to support upgrades at temples, shrines, castles, palaces and historic residences.

Matsue Castle in Shimane Prefecture has installed new flame and smoke detectors as well as a replacement sprinkler system.

Zenkoji Temple in Nagano has introduced high-sensitivity smoke detectors and set up a dedicated 24-hour self-defence fire brigade for emergency response.

Officials said progress has slowed because some sites lost income during the Covid-19 pandemic, material costs rose and some stakeholders disagreed over how to install upgrades without affecting historic architecture.

Some projects have also been slowed by access issues at sites in mountainous areas.

Moriyama said: “We understand there are various individual circumstances that are the reason for the delays.”

Authorities have not identified the sites where work has yet to begin because they said publishing that information could create security risks.

With the original five-year programme nearing its end, the government has introduced a new four-year scheme that will continue support for sites still needing improved fire protection.

The revised scheme will also fund measures to improve resistance to earthquakes and flooding.

Under the updated timetable, the Agency for Cultural Affairs expects the remaining fire safety improvements at priority sites to be completed by 2035.

Work to rebuild Shuri Castle is nearing completion, with the structures around the hilltop courtyard expected to reopen to visitors in the autumn.

Upcoming Webinar: How the UK second staircase mandate affects evacuation systems and building design

IFSJ webinar to examine the UK’s second staircase mandate and its impact on tall building fire safety design

International Fire and Safety Journal (IFSJ) will host a webinar examining the implications of the UK’s second staircase mandate for fire safety strategy, system design and evacuation planning in tall residential buildings.

Register now

Titled “Redefining Escape: What the UK’s Second Staircase Mandate Means for Global Fire Safety Design”, the webinar will take place on 11 May 2026 at 11:00 BST.

The session will discuss how the introduction of mandatory second staircases in all new residential buildings over 18 metres is influencing how tall buildings are designed, occupied and managed.

While the requirement is rooted in UK legislation, the discussion will also address the broader relevance of these regulatory changes for international fire safety design and operational practice.

The webinar will examine how the second staircase requirement affects evacuation strategy in multi-stair buildings, including considerations around escape planning, compartmentation, evacuation sequencing and system zoning.

It will also address what building owners and facilities teams should consider to ensure life safety systems remain effective, maintainable and operational across multiple escape routes.

Another focus of the session will be the role of emergency lighting and dynamic signage in supporting evacuation behaviour, particularly as building layouts become more complex.

The discussion will also examine how coordinated approaches to lighting, detection and wayfinding systems can support clearer evacuation routes and reduce complexity during an emergency.

Speakers

The webinar will feature insights from two industry specialists with extensive experience in fire detection and life safety systems.

Martin Green, Commercial Training & Support Manager, Hochiki Europe, has more than 30 years of experience in the fire safety sector, including nearly two decades with Hochiki Europe.

He delivers training and technical support across the UK and provides accredited CPD and practical guidance for those responsible for the design, installation and management of life safety systems.

His expertise covers fire alarm and emergency lighting design, regulatory compliance and fire safety strategy.

He will be joined by Mick Hall, Regional Sales Manager, Hochiki Europe, who has spent the past decade working with architects, consultants, installers and building owners across the UK.

His experience includes system design, application engineering and integrated life safety approaches, including dynamic emergency communication and wayfinding systems.

Together, the speakers bring more than forty years of combined experience in the fire safety market, offering technical insight into the practical implications of the second staircase mandate.

Who should attend

This webinar will be relevant for professionals involved in the design, operation and management of tall buildings, including:

  • Architects and building designers
  • Developers, building owners and asset managers
  • Facilities and estates teams
  • Health and safety and fire safety professionals
  • Fire safety installers and electrical engineers

Although the session focuses on UK regulation, it will also provide useful insight for international audiences seeking to understand how regulatory change is influencing tall building fire safety design and operational practice.

Register for the webinar

The webinar will take place on 11 May 2026 at 11:00 BST.

To register, visit: https://attendee.gotowebinar.com/register/4263019240448011096

Ranger acquires MarkOne to expand West Midlands fire safety coverage

Ranger expands in the West Midlands

Ranger Fire & Security has acquired Midlands-based MarkOne Safety Solutions, extending its presence in the West Midlands and adding to its fire safety service capacity across the UK.

Ranger Fire & Security announced the deal on 11 March and said it was the group’s 16th acquisition since its formation in early 2024 and its third acquisition of 2026.

MarkOne Safety Solutions works in the design, supply, installation, commissioning and maintenance of fire safety and emergency lighting systems.

The business has operated for nearly 20 years and serves customers ranging from small retail outlets to large multi-site corporate organisations.

Its work covers the full lifecycle of fire safety systems, from initial design and installation through to commissioning, service and maintenance.

Ranger said the acquisition builds on its earlier purchase of Ignis Fire Protection, another Midlands-based business, and is intended to improve regional resourcing, operational efficiency and service coverage.

Ranger and MarkOne leadership set out next steps

Ranger said MarkOne will continue to operate under the existing leadership of Managing Director Mark Haynes, with the same team remaining in place.

The company said the business will also gain access to wider operational support across the group, along with opportunities to work with other specialist companies in the portfolio.

Mark Bridges, CEO of Ranger Fire & Security, said: “MarkOne is an excellent addition to the Ranger Group, significantly strengthening our presence in the West Midlands.

“The team brings deep technical expertise across the design, supply, installation, commissioning and maintenance of fire safety systems, making the company a natural fit as we continue building a single, national platform to meet all fire and security needs.

“Following our earlier acquisition of Ignis Fire Protection, MarkOne further enhances our regional footprint in the Midlands and allows us to provide customers with an even broader range of high-quality fire safety services.”

Haynes said: “Joining Ranger represents an exciting new chapter for MarkOne.

“Since the business was founded, our focus has been on delivering high-quality fire safety systems for our customers, from design and supply through to installation, commissioning and ongoing maintenance.

“Becoming part of the Ranger Group allows us to build on that foundation and take the company to the next level.

“With the additional support, expertise and network that Ranger provides, we will be able to continue delivering the high standards that our customers have come to expect, while expanding the reach of our services across the region.”

Ranger acquisition strategy continues

Ranger said the MarkOne deal forms part of its strategy to bring regional operators into a national fire and security platform covering the UK and Ireland.

The company said it has backing from Hyperion Equity Partners and is seeking to grow through acquisitions as well as investment in technology and talent.

The latest acquisition adds another Midlands business to the group as Ranger continues its expansion activity in 2026.

New Scotland wildfire strategy launched after record 2025 fire season

Scotland action plan sets out wildfire response changes

A new strategic action plan has been launched to strengthen wildfire prevention, preparedness and response across Scotland following the country’s most severe wildfire season in recent memory.

The Scottish Fire and Rescue Service (SFRS) said the plan is designed to improve coordination between agencies, expand operational capability and increase public awareness of wildfire risk.

Scotland’s high-risk wildfire period, traditionally between March and May, has expanded in recent years.

Firefighters spent more than 100 days responding to more than 230 wildfires during 2025.

The executive summary of the Wildfires: strategic action plan records 241 wildfires during the year, including the Carrbridge and Dava Moor fire which burned nearly 10,000 hectares and is described as the UK’s largest recorded wildfire.

The plan was developed in partnership with SFRS with input from His Majesty’s Fire Service Inspectorate alongside other stakeholders.

It sets out coordinated actions under three areas covering prevention, preparedness and response.

Measures include strengthening public awareness of wildfire risks, investing in wildfire vehicles and equipment and developing a multi-agency Concept of Operations ahead of the 2026 wildfire season.

Local and regional Incident Response Plans will also be enhanced to strengthen protection for responders, rural communities and Scotland’s natural environment during periods of heightened wildfire activity.

Additional actions include reviewing and expanding the Community Asset Register and examining a mountain rescue-style approach to trained wildfire volunteers with a potential trial in Cairngorms National Park.

Scotland equipment investment and operational preparation

SFRS said it reviewed the 2025 wildfire season and has invested in equipment, training and specialist capability.

Four new wildfire support units with enhanced equipment have been placed in Alford, Oban, Galashiels and Dornoch.

Two interim wildfire units have also been introduced in Lockerbie and Thurso.

Controlled burn training is being delivered to support operational readiness.

The service worked with partners to review wildfire incidents from 2025 through the Scottish Multi-Agency Resilience Training and Exercising Unit (SMARTEU).

Recommendations from the SMARTEU debrief will be progressed through the Scottish Wildfire Forum.

More than 30 fire stations across Scotland are already equipped with dedicated wildfire resources.

Wildfire tactical advisers are also available to provide strategic support during incidents.

To inform the public, SFRS issues Wildfire Danger Assessments through its website and social media channels when weather conditions increase wildfire risk.

SFRS Deputy Assistant Chief Officer Kenny Barbour said: “Wildfires continue to pose an increasing threat to Scotland’s rural communities and natural environment.

“We welcome the strategic action plan, which is an essential step in ensuring our firefighters, land managers, public bodies and partners can enhance their collective response to wildfires.

“It is vital for everyone to play their part in protecting Scotland’s natural environment with responsible outdoor behaviour.

“Never assume a small fire, like a campfire or portable BBQ, is safe and harmless.

“The smallest spark or ember in dry conditions can quickly lead to wildfire destroying large parts of the countryside.”

Scotland ministers link plan to future wildfire preparedness

SFRS said Minister for Community Safety Siobhian Brown and Agriculture Minister Jim Fairlie joined the service at Pitlochry fire station to present wildfire appliances and equipment as the annual wildfire awareness campaign launched alongside the action plan.

Brown said: “Last year’s wildfires were a warning that we must be prepared for this to be a more regular occurrence as a result of climate change.

“The strategic action plan will improve coordination between the SFRS and other responders during wildfires and includes the development of Incident Response Plans to strengthen the protection of responders, rural communities, and the natural environment during periods of heightened wildfire activity.

“It will also see the Community Asset Register – a list of volunteers and equipment to help with wildfire response – reviewed and expanded.”

Fairlie said: “All of us who saw the devastation caused by last year’s fires know that it took an incredible effort to get them under control and I would like to repeat our thanks to all the SFRS staff, landowners, managers, keepers and workers who stepped in.

“So many communities stepped up to save their local landscape and the species that live there and this plan is intended to help us better prepare for the future.

“Each of us has a part to play in preventing wildfires and must be mindful of their behaviour when enjoying our wonderful countryside during the dry months to ensure we do not do anything or leave behind litter that could ignite a fire.”

The strategic action plan sets out a coordinated approach intended to strengthen Scotland’s wildfire resilience ahead of the 2026 wildfire season and in future years.

Angus Fire permit draft explains proposed PFAS treatment measures

Angus Fire permit moves to draft decision stage

The Environment Agency has opened a consultation on its minded-to decision to grant a permit variation for Angus Fire’s site in High Bentham, North Yorkshire.

The Environment Agency said the application is for an effluent treatment plant to reduce PFAS contamination in collected rainwater and future rainwater falling onto key areas of the site.

The consultation runs from Thursday 5 March until the end of Wednesday 1 April 2026.

The agency said it had reviewed comments and evidence from the original consultation last summer and could not find a reason to refuse the application at this stage.

It said the draft decision document explains how comments from the earlier consultation were considered and sets out the decision-making behind the draft outcome.

The draft permit document sets out the conditions the operator would need to meet if the permit variation is granted.

The Environment Agency said people can respond through its Citizen Space consultation website or by email.

Angus Fire site plans and PFAS treatment

Previously, Angus Fire manufactured and tested firefighting foam at the site, and the foam is known to have contained per- and polyfluoroalkyl substances (PFAS).

The Environment Agency said those PFAS chemicals contaminate rainwater when it falls onto key areas of the site.

That rainwater has been collected so it can be treated to reduce PFAS substances.

The application covers an effluent treatment plant intended to reduce PFAS in stored rainwater and in future rainwater from the site.

Once treated at the plant, the rainwater would be discharged to the River Wenning.

The proposed PFAS level remaining in the treated rainwater discharged into the river would be in line with levels currently accepted as best practice for PFAS treatment processes.

The operator no longer manufactures firefighting foam at its High Bentham site.

The application relates to treating rainwater affected by the site’s previous manufacturing processes.

Angus Fire consultation invites public responses

John Neville, Area Environment Manager for the Environment Agency, said: “We have carefully considered all of the documents, as well as the consultation comments, and currently can’t find any reason to refuse the variation application.

“Our regulatory controls are in place to protect people and the environment and we are carrying out a detailed and robust assessment.

“I’d encourage interested parties to view the decision document and send us their comments. We’ll then make our final decision once we’ve reviewed those responses.”

The Environment Agency said it may only refuse a permit application if it does not meet one or more legal requirements under environmental legislation.

It said that where an application shows a site can operate in line with current environmental regulations and provide a high level of protection for the environment and human health, it is legally required to issue a permit.

The consultation documents explain what the agency can take into account when deciding the application, and people who cannot respond online or by email can contact the Environment Agency by phone.

Engine bay defence: MusterFire International tackles hidden fire risks in compact machinery

Hazem Omran, Product Engineering Manager at MusterFire International, explains how compact misting systems protect small mobile machines from rapid engine compartment incidents

Fires in engine compartments of small mobile machines remain a persistent operational and safety risk across mining, agriculture, construction, transport, forestry, and waste handling sectors.

These machines operate in demanding environments characterised by vibration, dust, high ambient temperatures, and continuous mechanical load.

Within the confined space of an engine bay, hot exhaust components sit in close proximity to fuel lines, hydraulic systems, electrical harnesses, and accumulated debris.

When a fault occurs – whether from a ruptured hose, electrical short, or oil mist contacting a turbocharger – ignition can develop rapidly and escalate before an operator is even aware of the event.

As Product Engineering Manager at MusterFire International, my responsibility is to ensure our fire suppression systems are engineered to perform reliably under precisely these conditions.

Our focus is on automatic fire suppression for mobile and transportable equipment.

The objective is straightforward: detect a fire at its earliest stage and suppress it automatically before it becomes a major asset loss or safety incident.

Why smaller machines lack protection

Historically, compact mobile machinery has presented a protection gap.

Larger haul trucks and heavy mining assets are commonly fitted with engineered suppression systems.

Smaller equipment – such as compact loaders, skid steers, small excavators, and light transport vehicles – often operate with limited engineered protection due to space constraints, weight sensitivity, and perceived installation complexity.

Yet these smaller assets face the same ignition risks within tightly enclosed engine compartments.

The Muster Misting System was developed to address that gap.

It is a lightweight, self-contained suppression solution designed for engine compartments up to 2.25 cubic metres.

Rather than relying on high mass or bulky hardware, the system uses a fine mist discharge architecture that maximises extinguishing efficiency within a compact footprint.

A misting fire suppression system distributes extinguishing agent as atomised droplets through multiple strategically positioned nozzles.

The droplet size is intentionally small.

This significantly increases surface area, improving heat absorption when the droplets encounter flame or hot surfaces.

In a confined engine compartment, this fine mist expands rapidly, filling voids and surrounding components more uniformly than a coarse discharge pattern.

The agent used in the Muster Misting System is a 1 per cent fluorine-free foam solution.

The selection of fluorine-free chemistry reflects both environmental responsibility and forward-looking regulatory alignment.

There is increasing scrutiny globally on fluorinated compounds.

By adopting fluorine-free foam, we reduce environmental persistence while maintaining effective suppression performance.

From a technical perspective, the 1 per cent concentration is sufficient because the misting architecture enhances agent efficiency.

When the fine droplets contact flame or high-temperature surfaces, they absorb heat rapidly and convert to vapour.

This vapour expansion extracts thermal energy from the combustion zone, lowering temperatures below the threshold required to sustain ignition.

Simultaneously, the foam component forms a thin suppressive film over flammable liquid surfaces such as diesel or hydraulic oil.

Many engine compartment fires involve atomised fuel or oil contacting hot components.

By reducing vapour release and cooling the environment, the system interrupts the combustion cycle.

Activation is achieved through Loss-of-Pressure technology.

A pressurised detection tube is routed throughout the hazard area, typically along high-risk components such as turbochargers, exhaust manifolds, and hydraulic assemblies.

Under normal conditions, the tube maintains system pressure.

When exposed to abnormal heat levels indicative of a fire, the tube ruptures at the hottest point.

This rupture creates an immediate pressure drop that mechanically triggers the discharge valve on the agent cylinder.

This method offers several advantages in mobile environments.

It is direct-acting and localised, meaning the system responds precisely at the ignition source.

It does not depend on external power supply, electronic sensors, or software for primary activation.

In a fire event where electrical systems may be compromised, mechanical activation ensures reliability.

At the same time, the pressure circuit can be continuously monitored via an indicator panel and integrated with digital diagnostics to confirm system readiness.

Nozzle placement inside an engine bay is determined through structured hazard assessment.

We analyse engine layout, airflow, ignition sources, and fluid pathways.

High-risk zones typically include turbochargers, exhaust manifolds, alternators, starter motors, fuel injection systems, and hydraulic pump assemblies.

The objective is to create overlapping spray patterns that achieve uniform mist distribution and avoid untreated areas where flame could persist.

Depending on compartment size and geometry, compact machines generally require two to four nozzles.

For engine bays approaching the 2.25 cubic metre design limit, additional nozzles may be specified to maintain coverage density.

Engineering calculations consider enclosure volume, discharge characteristics, and target concentration levels.

Configurations are validated against performance testing to ensure consistency across installations.

Mechanical activation in harsh conditions

Installation has been engineered for both OEM integration and retrofit application.

On existing equipment, the process typically involves mounting the cylinder in a protected but accessible location, routing the detection tube around critical heat sources, and installing distribution tubing and nozzles inside the engine compartment.

The most common challenges relate to space constraints and routing discipline.

Compact machinery provides limited clearance, and tubing must be secured away from moving parts and sharp edges while maintaining correct bend radii.

Vibration management is also critical in mobile plant.

Secure bracket design and correct fastening procedures ensure long-term durability.

Because the misting system is comparatively lightweight and compact, it integrates more readily into smaller machines without significant structural modification.

Digital monitoring is provided through Muster360.

When integrated, Muster360 enables real-time visibility of system status, including pressure integrity, activation state, and fault conditions.

For fleet managers overseeing dispersed assets, this reduces reliance solely on manual inspection cycles.

Alerts can indicate pressure anomalies or discharge events, and historical logs provide traceable maintenance records.

Monitoring, records and compliance

In regulated industries such as mining, documented compliance and asset traceability are increasingly important.

Cloud diagnostics support audit readiness and provide assurance that suppression systems remain operational across the fleet.

Performance validation is fundamental.

The Muster Misting System is certified to AS 5062:2022, which defines requirements for fire protection systems on mobile and transportable equipment in Australia.

This standard addresses design, installation, and performance verification under realistic fire conditions.

In addition, the system has been tested to UL 1254, which specifies controlled performance testing for engine compartment hazards.

Certification and recognised testing provide independent verification that the system performs as intended under defined scenarios.

For end users, this reduces operational risk, supports insurance expectations, and demonstrates due diligence in asset protection strategy.

Looking ahead, compact misting suppression systems should be viewed as one layer within a comprehensive fire risk management framework.

Preventive maintenance, leak management, housekeeping, and operator awareness remain essential.

However, engine compartment fires can escalate in under a minute.

Automatic suppression addresses the time gap between ignition and human response.

As machinery becomes increasingly compact and thermally dense, lightweight and modular suppression technologies will become more relevant.

Compact systems expand engineered protection coverage to asset classes that were historically under-protected due to packaging constraints.

From an engineering perspective, the objective is controlled and measurable risk reduction: limiting downtime, reducing repair costs, protecting personnel, and aligning with evolving compliance frameworks.

Compact misting fire suppression represents a technically sound and scalable approach to improving safety outcomes across small mobile machinery fleets.

This was originally published in the March 2026 Edition of International Fire & Safety Journal. To read your FREE copy, click here.

Rosenbauer to supply 26 Dutch airport fire vehicles

Rosenbauer airport fleet order for Dutch defence

The Dutch Ministry of Defence has awarded a contract for 26 Rosenbauer PANTHER 6×6 vehicles to renew the airport firefighting vehicle fleet in the Netherlands.

Rosenbauer announced that the order will be handled by Kenbri Fire Fighting, its exclusive partner in the Netherlands, and the vehicles will replace the crash tenders currently in use at airports.

Andreas Zeller, Chief Sales Officer at Rosenbauer International AG, said: “This order once again highlights the strong international position of the Rosenbauer PANTHER as a leading aircraft rescue firefighting vehicle.

“Together with our long-standing partner Kenbri, we’re making a significant contribution to the safety and operational capability of local airport fire services.

“The fact that we are part of a comprehensive fleet modernization program confirms that customers have confidence in our technology, quality, and service expertise throughout the entire product life cycle,”

Rosenbauer vehicles include HRET and roof turret configurations

Rosenbauer said seven vehicles will be delivered with high reach extendable turrets (HRET) and 19 vehicles will be equipped with roof turrets.

The HRET units include an extendable telescopic arm that reaches around 16 metres and allows firefighting from a distance.

Water, foam or extinguishing powder can be dispensed with precision through the extinguishing arm.

The roof turret vehicles use electrically remote controlled turrets with flow rates of up to 9,000 litres per minute and throw ranges exceeding 90 metres.

The vehicles accelerate from 0 to 80 km/h in less than 33 seconds to support rapid response to major fires.

PANTHER 6×6 designed for airport firefighting operations

Rosenbauer said the PANTHER 6×6 is designed for airport use and includes high engine performance and off road capability.

The vehicles also include high extinguishing agent capacity with pumping and monitoring systems designed for rapid firefighting operations.

The crash tested cabin is ergonomically designed with all round visibility and assistance systems intended to support crew safety and comfort.

The vehicles comply with international International Civil Aviation Organization (ICAO) and National Fire Protection Association (NFPA) standards and are tailored to the operational requirements of Dutch airport fire services.

CONAF study details wildfire prevention gains during Chile fire season

Wildfire prevention findings from Chile

New analysis published in January 2026 found that wildfire prevention and response measures in Chile avoided substantial damage during the severe 2023 fire season.

The study by Jorge Saavedra, Daniela Alegría, Gonzalo Tapia, Ana Prados and Mackenzie Allen used modelling and post-fire assessments conducted by the National Forestry Agency (CONAF) to examine wildfire impacts and avoided losses.

During the Santa Ana fire in the Biobío region in February 2023, about 108,944 hectares burned.

Modelling suggested the fire could have affected about 242,093 hectares.

That left an estimated 133,149 hectares spared.

The analysis also found that 17,321 homes were identified as potentially at risk.

Around 15,171 of those homes were ultimately spared from fire damage.

Across January and February 2023, CONAF estimated that prevention and response efforts helped prevent about USD 2 billion in economic losses.

That figure was about 20.8 times greater than the country’s USD 101 million budget for fire control and prevention activities.

The same analysis indicated that about 64,477 people and 46,634 structures avoided wildfire impacts during that period.

How the analysis measured avoided losses

CONAF stated that it has been analysing avoided wildfire losses since 2014 – 2015 to support wildfire risk management policy and assess prevention strategies.

One method uses fire behaviour simulation to estimate potential spread under given conditions.

Another method uses fire potential polygons to model areas that could have burned if suppression and mitigation efforts had not taken place.

These models are then compared with the actual burned area after a fire.

The difference between the modelled and observed burn area is used to estimate the land, property and communities protected by prevention and response actions.

That avoided burned area can also be combined with population data, property values and vegetation assessments to estimate economic impacts and the number of people and structures protected from damage.

Community measures and vegetation protection

The analysis also examined avoided losses linked to vegetation damage and community-level wildfire prevention work.

According to the figures presented, avoided vegetation-related economic losses in the affected regions during the 2023 fire season reached about USD 786 million.

The study said these figures reflect the value of forests, agricultural land and natural vegetation protected through prevention and response measures.

Chile has also expanded community-based wildfire prevention through CONAF’s Community Preparedness Program.

The programme works with residents in high-risk rural areas and wildland-urban interface zones to develop participatory wildfire prevention plans.

Activities include training workshops on household protection measures and the development of local emergency response procedures.

Vegetation management measures are also used in interface zones, with pruning and thinning used alongside fuel breaks to reduce fuel continuity and slow fire spread.

The authors said the Chilean case study shows how fire modelling, earth observation data and post-fire analysis can support wildfire mitigation and policy development.

Madrid-based Agustin Polo joins Hyfire in global product marketing post

Hyfire appoints new global product marketing lead

Hyfire has appointed Agustin Polo as Global Product Marketing Manager, based in Madrid, to support the international promotion of its wireless fire safety systems and contribute to its global product marketing strategy.

Hyfire said Polo will work with teams across the company and its parent organisation, Orama, on product launches, digital initiatives and wider transformation programmes.

Polo was born in Argentina and raised in Italy.

He completed his Bachelor’s degree in Milan before studying for a Master’s degree in Vienna, Austria.

He holds dual citizenship and is fluent in Italian, Spanish and German.

Following his studies, he worked with organisations in Germany, France, the United Kingdom and the United States, gaining experience across several international markets.

Polo said: “What really drew me to Hyfire was their technological innovation.

“Especially the idea of using wireless systems as a launch pad toward digital transformation in fire safety.

“It is something that, in my opinion, this sector really needs right now to gain that digital momentum.”

Polo sets out wireless growth focus

Hyfire said Agustin Polo, Global Product Marketing Manager, will coordinate with teams across the organisation to support the marketing of the company’s wireless fire safety technologies as it seeks to strengthen its position in wireless fire detection systems and expand internationally.

The role includes involvement in digital product development, product launches and company-wide transformation initiatives through Hyfire’s position within the Orama group.

Polo said the opportunity to contribute to global projects through that structure was part of the role’s appeal.

Polo said: “We must be the centre of wireless excellence in all of Europe, and eventually the world.

“We can achieve this by elevating our product marketing and showcasing how Hyfire’s products can be key solutions in various sectors and cases.”

He also said geographic expansion would be important as the company introduces its technologies into additional international markets.

Polo said: “I love keeping up to date with the latest in technological innovation, from artificial intelligence to various digitalisation.

“I believe that it’s important to keep an open mind as embracing change is the only way of achieving greatness.”

Outside work, Polo said: “I’m passionate about sports, specifically football.

“I played for a long time, I’d say I’m almost a former football player.

“But I also love music, I play the guitar and am quite fond of American Country music.”

The appointment places Polo in a role focused on international product marketing as Hyfire continues to promote its wireless fire safety systems across more markets.

Meiko expands Interschutz showcase with workshop and mobile cleaning units

Meiko to show SCBA and PPE systems

Meiko will present new cleaning and disinfection systems for self-contained breathing apparatus (SCBA) and other personal protective equipment at Interschutz from 1 to 6 June 2026.

The company’s presence will span three exhibition areas, including stand L21 in hall 14, the open-air area between halls 11 and 12 and the outdoor venue for the FireFit European Championships between halls 7 and 9.

Stand L21 in hall 14 will include a new prototype machine for cleaning respiratory protective equipment in a footprint of less than one square metre.

The machine is intended for smaller fire services with lower throughput.

Meiko will also present new features for its TopClean range.

Its TopClean D PPE decontamination machine uses a reversing wash system to remove combustion residue from SCBA sets, and an optional brush has been added for a more thorough clean.

A prototype wastewater filter system will also be shown, designed to capture contaminants before they reach the sewerage network.

The company’s display will also show the workflow from the dirty side to the clean side of an SCBA workshop through planning examples for fire service and industrial settings.

Meiko to demonstrate mobile workshop

Meiko stated that its open-air display between halls 11 and 12 will feature a mobile SCBA workshop developed with vehicle manufacturer Mosolf.

The trailer is designed for extended incidents such as wildfires.

It is divided into a dirty side and a clean side to reduce cross-contamination.

The unit includes facilities for cleaning, disinfection, drying and testing of respiratory protective equipment.

Live demonstrations will allow visitors to watch the process and take part in individual stages.

Meiko equipment to support FireFit operations

Meiko said a transport vehicle fitted with its equipment will be used to service SCBA sets supplied to competitors at the FireFit European Championships during the fair.

The championships will take place at Interschutz, with firefighters from around the world competing in individual and team events across the event.

FireFit Europe uses the vehicle as a plug-and-play mobile SCBA workshop for around ten events each year in several countries.

The unit is designed for rapid deployment and allows equipment to be cleaned in a sheltered environment in different weather conditions.

A screen near the competition area will show real-time footage of PPE being cleaned and prepared inside the vehicle.

Visitors will also be able to enter the vehicle in small groups during breaks between events and inspect the equipment.

Appointments for meetings at the event can be booked in advance through Meiko’s Interschutz page.