PFAS litigation risks in UK: Legal challenges grow for businesses amid regulatory scrutiny

UK inquiry into PFAS regulation highlights legal exposure

A parliamentary inquiry into per- and polyfluoroalkyl substances (PFAS) is drawing attention to gaps in the UK’s chemical regulation and increasing the likelihood of legal claims against companies that manufacture or supply PFAS-containing products.

According to Pinsent Masons, businesses using PFAS face a growing risk of litigation due to the limited scope of current UK regulations.

PFAS are used in a wide range of products, including firefighting foams, food packaging, electronics, textiles and cleaning chemicals.

The Environmental Audit Committee is examining whether the UK’s regulatory regime—known as UK REACH—is sufficient.

The Committee will compare the UK’s approach with international frameworks such as those in the EU and US.

It has also opened a call for submissions on whether a precautionary or risk-based approach to PFAS regulation should be adopted, with a deadline of 26 May 2025.

Regulatory lag behind EU and US raises litigation concerns

Katie Hancock, a legal expert at Pinsent Masons, said that regulatory divergence from the EU following Brexit has heightened legal exposure for UK businesses dealing with PFAS.

Hancock said: “We have already seen how PFAS litigation is growing in other parts of the world, with a ‘class action’ claim against Apple in the US perhaps the latest high-profile example in the area of popular consumer goods.”

Hancock also noted that the perception of weaker UK regulation could attract more legal challenges, regardless of compliance with domestic rules.

She cited a judicial review that was brought—though ultimately unsuccessful—against the Environment Agency’s handling of PFAS oversight as an example of mounting legal interest.

Firefighting foam ban signals regulatory movement

Current UK regulations place minimal restrictions on PFAS.

However, from July 2025, the use of Perfluorooctanoic Acid (PFOA) in firefighting foams will be banned.

OHEAP Fire and Security stated that the change “will not affect many units at all as the chemical that is being banned hasn’t been used for more than 10 years.”

The Health and Safety Executive (HSE) is assessing additional restrictions on wide dispersive uses, including coatings and cleaning agents.

It is also examining consumer goods that may release PFAS into air, water or soil.

Agricultural sector highlighted as at-risk area for PFAS claims

According to Hancock, agriculture is another sector where PFAS litigation may emerge.

She said outdated laws governing the use of sewage sludge on farmland could expose suppliers to legal challenges.

“There is a risk that land owners could raise claims against sludge suppliers in relation to PFAS content in the sludge,” Hancock said.

She referenced examples from the US, where such claims have been pursued, and from Germany, where a compensation fund was set up in 1998 to address damage linked to agricultural use of sewage sludge.

Hancock said: “Industry in the UK would benefit from further guidance from government and regulators on this topic.”

PFAS litigation risks in UK: Legal challenges grow for businesses amid regulatory scrutiny: Summary

The Environmental Audit Committee in the UK has launched an inquiry into PFAS use and regulation.

The inquiry will examine the current UK regulatory framework, including UK REACH, and compare it with standards in the EU and US.

Legal expert Katie Hancock from Pinsent Masons warned that regulatory gaps since Brexit have increased litigation risks for UK businesses using PFAS.

A forthcoming ban on PFOA in firefighting foams takes effect in July 2025.

The HSE is also reviewing further PFAS restrictions.

Legal risks have also been identified in the agricultural sector, where outdated sludge regulations could lead to PFAS-related claims.

A judicial review against the Environment Agency has already shown an increased legal focus on PFAS in the UK.

The Committee is accepting industry submissions until 26 May 2025.

PFAS destruction technology tested in Minnesota waste facility

PFAS trial launched at Lake Elmo site in the United States

General Atomics Electromagnetic Systems has reported that its commercial PERSES waste destruction system is being delivered to a waste management facility in Lake Elmo, Minnesota.

The deployment is part of a demonstration project led by environmental remediation firm Bay West LLC and funded by the U.S. Army Engineer Research and Development Center (ERDC).

The trial aims to show PERSES’ capacity to destroy per- and polyfluoroalkyl substances (PFAS) waste at industrial scale.

The system will remain at the Lake Elmo facility for approximately four weeks before being moved to other locations for additional demonstrations under separate contracts.

PERSES system previously verified in full-scale testing

In 2024, Bay West carried out trials at the General Atomics Electromagnetic Systems testing site in San Diego.

Analysis of the results, submitted to ERDC, indicated PERSES achieved 99.99% or greater PFAS destruction across various waste materials from both public and private sources.

The upcoming Lake Elmo trial will involve processing PFAS and other organic waste from sources including Aqueous Film-Forming Foam, landfill leachate, biosolid sludge, soils and sediment, and filtration materials such as granular activated carbon and resin beads.

Government and community support for demonstration project

Scott Forney, president of General Atomics Electromagnetic Systems, said: “Minnesota’s government leadership, as well as states across the nation are actively implementing strategies to eliminate PFAS from the environment and mitigate the adverse effects these ‘forever chemicals’ have on public health and safety.”

He added: “We are excited to bring the destruction power of PERSES to Lake Elmo as local, state, and federal government agencies continue to evaluate PERSES’ capabilities to eliminate PFAS from a myriad of waste streams.

“We appreciate the efforts the Lake Elmo city council and local community have made to support this project and look forward to a successful demonstration program.”

Bay West and ERDC roles in research and remediation

Bay West LLC is overseeing the demonstration project.

The company is based in St. Paul, Minnesota, and offers environmental consulting and remediation services for government and commercial clients.

ERDC is part of the Office of the Assistant Secretary of Defense for Research and Engineering.

It provides scientific and engineering expertise to U.S. military and civilian agencies on environmental and infrastructure challenges.

PFAS destruction technology tested in Minnesota waste facility: Summary

General Atomics Electromagnetic Systems has delivered its PERSES waste destruction system to a waste management facility in Lake Elmo, Minnesota, for a four-week demonstration.

The project is managed by Bay West LLC and funded by the U.S. Army Engineer Research and Development Center (ERDC).

It aims to evaluate the system’s industrial-scale performance in destroying per- and polyfluoroalkyl substances (PFAS) across a range of waste media.

In 2024, PERSES achieved 99.99% or greater PFAS destruction efficiency in full-scale tests conducted in San Diego.

The Lake Elmo trial will process materials including firefighting foam, landfill leachate, sludge, soils, and treatment filtration residues.

Following this demonstration, the system will be relocated to other test sites.

Bay West is a Minnesota-based environmental services firm.

ERDC is a U.S. Department of Defense research body supporting environmental and infrastructure science across military and civilian domains.

The Three C’s of Suppression, with HEN Nozzles   

Ray McCormack, Director, Business Development at HEN Nozzles, explains how coverage, cooling and contraction enhance suppression and how modern nozzles improve efficiency and firefighter safety 

Rapid fire suppression is governed by three fundamental principles—coverage, cooling and contraction. Each “C” represents a critical component of the suppression process that must be delivered in rapid succession to effectively suppress a fire. However, few stream patterns possess the intrinsic ability to achieve all three simultaneously.  

Instead, successful suppression with traditional streams often relies on coordinated manual nozzle manipulation to achieve the necessary performance. In other words, the stream can’t do much by itself because it cannot interact with the fire environment at a rate that provides rapid suppression. The reason is one or more of the C’s are difficult to obtain using traditional streams. 

Fire streams background 

Traditionally, two types of nozzles have been used for delivering fire streams: the smoothbore nozzle and the combination fog nozzle. The smoothbore nozzle generates a solid stream consisting of large water droplets in a tight, cylindrical pattern. In contrast, the combination fog nozzle can produce either a wide fog pattern or a straight stream, both of which consist of small droplets. 

Recent advances in nozzle technology have introduced the combination smoothbore nozzle, also known as the combination blade nozzle. This innovative design can deliver either a wide blade stream or a solid stream. Notably, the blade stream features large droplets arranged in a concentrated linear edge, providing enhanced performance in fire suppression. 

Coverage 

Coverage refers to the ability of a stream to blanket the fire area effectively. Straight and solid streams must be intentionally broken up to provide coverage beyond their flow shape. Whereas a pre-broken stream like the HEN BLADE provides a linear pattern of large droplets that inherently offers wider coverage. A fog stream is a hollow conical stream shape that is broken into small droplets and provides a circular band of coverage. 

For standard streams, nozzle movement plays a crucial role in optimizing coverage. With straight, solid or fog* streams movement is typically provided using a given letter pattern like O or Z or a wall ceiling wall approach to maximise their area of effect. In contrast, the blade stream offers enhanced coverage with simpler nozzle movements, such as up-and-down or side-to-side sweeps.

This not only centers the stream more effectively minimises nozzle fatigue, allowing firefighters to maintain effective coverage with less effort.

Ray McCormack

The streamlined application methods associated with the blade stream can raise the operational proficiency of the department’s firefighters, offering an intuitive approach that ensures extensive coverage of the fire space. 

Achieving broad coverage is imperative for rapid knockdown of the fire. A straight or solid stream relies on contact with a surface to break apart and cover a larger area. In contrast, the blade stream is designed to deliver a pre-broken, large-droplet, linear stream that naturally covers a wide area without depending on external factors. Its application is straightforward and replicable, making it an attractive option for both seasoned firefighters and those in training. 

Cooling 

Modern fires are characterised by high heat release rates that can quickly overwhelm suppression efforts. Effective cooling is therefore paramount and the blade stream addresses this need by delivering cooling benefits in two distinct locations simultaneously.

As the blade stream expands from the nozzle, it forms a triangular pattern that intensifies cooling near the nozzle team. This expansion not only interacts with and pushes heat away from the firefighters but also contracts the heated gases toward the nozzle, a phenomenon that can be initiated early in an operation for a distinct safety advantage. 

The expanded stream pattern of the blade stream allows it to interact with a larger volume of heated space than narrow streams.

To visualise the difference, consider a broom: a narrow stream is akin to the broom’s handle, providing minimal cooling effect, whereas the brush represents the blade stream with its wide coverage.

Ray McCormack

This broad interaction zone results in more effective cooling, as the large droplets absorb heat more efficiently and deliver it across a greater area. 

The efficiency of the blade stream reduces the need for repetitive nozzle movements, particularly in expansive or corridor-type environments. With floor-to-ceiling coverage easily achieved, the blade stream not only cools the fire environment but also creates a safer zone for firefighter operations. Its design minimises the application rate required to cool the space, thus expediting fire knockdown and reducing water consumption. 

Contraction 

Contraction refers to the process by which heated gases are condensed or “contracted” faster than new steam is generated. Effective contraction is essential to reducing the fire’s intensity and preventing the rapid generation of steam, which can impede firefighter operations. The blade stream’s broad, linear pattern allows it to interact with a more substantial volume of gases, promoting rapid contraction through efficient heat absorption. 

As the blade stream projects from the nozzle, its large droplet composition allows it to penetrate the gas layers effectively. By absorbing heat from these layers, the droplets survive the high-temperature environment and descend onto burning materials, thereby aiding in the cooling and contraction of the gases.

In scenarios where heated gases accumulate above the firefighting team, a well-placed, long-range blade stream can effectively contract these layers, improving both safety and suppression efficiency. 

Ray McCormack

A critical aspect of achieving gas contraction is the initial targeting of the extreme gas layer, often by aiming the stream high to capture the hottest gases first. The blade stream, through its progressive capture from the lower to the upper reaches of the fire space, maximises gas contraction bilaterally across different layers. This not only enhances suppression efficacy but also serves as a force multiplier, reducing the overall water usage by rapidly stabilizing the fire environment. 

Conclusion 

When coverage, cooling and contraction are delivered in rapid, coordinated fashion, fire suppression becomes significantly more effective. The blade stream stands out as a superior tool in achieving these goals. Its design—characterised by an inherently broken, wide linear pattern—ensures extensive coverage, effective cooling and efficient contraction, all while minimizing the physical demands on firefighters. 

By simplifying nozzle movements and enhancing overall application efficiency, the blade stream not only improves suppression outcomes but also elevates firefighter safety. Its intuitive application makes it accessible for both experienced personnel and new recruits, ultimately contributing to a more responsive and effective fire suppression strategy. In modern firefighting, where every second counts, the blade stream provides a critical advantage in rapidly controlling fires and protecting lives and property. 

*Note: UL-FSRI does not endorse using 30-degree or larger fog cones for interior structural fire operations. 

This article was originally published in the April 2025 Edition of International Fire & Safety Journal. To read your FREE copy, click here.

Fomtec Enviro MIL approved by US Navy for fluorine-free fire foam standard

US Navy confirms approval of Fomtec Enviro MIL under MIL-PRF-32725(2)

Dafo Fomtec AB has received documentation from the United States Department of the Navy confirming that its fluorine-free foam concentrate, Enviro MIL, meets the requirements of type 3 under the MIL-PRF-32725(2) specification.

The update was received on 1 April and certifies that Enviro MIL conforms to the standard for fluorine-free fire extinguishing agents intended for land-based, freshwater applications.

Fomtec stated that Enviro MIL will be added to the Qualified Products List QPL-32725.

The foam will be available in 5, 55 and 265 US gallon containers once the list is officially updated.

Fomtec maintains supply of AFFF foam under legacy US military standard

While expanding its fluorine-free product line, Fomtec confirmed it continues to produce and distribute aqueous film forming foam (AFFF) concentrates that meet the older MIL-PRF-84385F specification.

Fomtec said that its AFFF 3M is fully compatible with other concentrates made to the same US military standard.

This compatibility allows users to mix and use the foam with other approved brands without affecting performance.

Fomtec added that it will continue supplying its high performance PFAS-containing foams as long as it is legally permitted to do so.

Product availability for both freshwater and saltwater users

Fomtec noted that the fluorine-free Enviro MIL foam is formulated for use in land-based, freshwater scenarios.

For end users operating in saltwater environments, or those not yet able to switch to fluorine-free solutions, Fomtec will continue providing legacy AFFF products to meet operational needs.

The company said this dual offering ensures availability for a wide range of fire suppression scenarios, depending on specific site requirements and legal regulations.

Contact information for MIL-SPEC foam enquiries

Fomtec invited interested parties with specific requirements related to MIL-SPEC foam concentrates to make direct contact for more information.

The company advised that all product-related queries, including requests for Enviro MIL and AFFF foam concentrates, can be directed to: info@fomtec.com.

Fomtec Enviro MIL approved by US Navy for fluorine-free fire foam standard: Summary

On 1 April, Dafo Fomtec AB received confirmation from the US Department of the Navy that its Enviro MIL fluorine-free foam concentrate complies with type 3 of MIL-PRF-32725(2), applicable to land-based, freshwater fire suppression.

The Qualified Products List QPL-32725 will be updated to reflect this approval and will list Enviro MIL in 5, 55 and 265 gallon sizes.

Fomtec also confirmed it continues to manufacture AFFF 3M to MIL-PRF-84385F standard.

The company stated that AFFF 3M remains fully compatible with other concentrates certified to the same specification.

Production and supply of PFAS-based foam concentrates will continue while legally permitted.

The announcement said that Enviro MIL is intended for freshwater use, while legacy AFFF products remain available for users operating in saltwater environments or not ready to transition.

For enquiries related to MIL-SPEC foams, contact can be made via info@fomtec.com.

Reacton backs UAE law requiring school bus fire suppression

L-R Hassan Hijazi (General Manager at TABRA), Sam Malins (CEO at Reacton), Khalid Rashid Al-Mazrouei (Managing Partner at TABRA)

New UAE regulation mandates fire suppression systems on school buses

Reacton Fire Suppression has reported that a new regulation issued by the United Arab Emirates government requires all school buses to be fitted with automatic fire suppression systems from 15 April 2025.

The regulation, UAE.S 5041:2021, is designed to improve safety for approximately 500,000 children travelling on 17,000 school buses daily.

The systems rapidly detect and extinguish engine fires, which is essential given limited evacuation time on school buses.

The regulation requires education providers to install the systems through an approved supplier as part of their annual vehicle check and registration process.

Reacton certified as first approved provider in the UAE

Reacton is the first company to be approved by the Emirates Safety Laboratory to supply fire suppression systems for school buses under the new standard.

Sam Malins, CEO of Reacton Fire Suppression, said: “Every parent across the UAE should be delighted that the UAE government has taken such a positive approach to fire safety on school buses.

“Fires can spread quickly on school buses without the right suppression equipment.

“With the implementation of these new rules, parents can send their children off to school with peace of mind that the vehicles they are travelling in are even safer than before.”

Installations advance through partnership with TABRA

Reacton systems are being installed in partnership with UAE-based transport safety company TABRA.

Khalid Rashid Al-Mazrouei, Managing Partner of TABRA, said: “The UAE government isn’t just raising the bar, it’s redefining international standards on fire safety and the protection of school children.

“Together, with our partners at Reacton, we’re proud to be on the front lines of this mission, rapidly deploying cutting-edge fire suppression systems across schools, associations and fleet operators.

“Within just a few hours, we can safeguard a school bus and every child who travels in it.”

To date, more than 2,500 systems have been installed by Reacton and TABRA, including in a project with Emirates Transport.

Reacton expands presence in UAE and regional fire safety sector

Reacton opened its UAE office in 2019, extending its operations from the UK.

From its base in Dubai, the company delivers customer support, technical training and system installation assistance to its regional partners.

TABRA provides professional installation services and has more than 27 years of experience in transport safety within the UAE.

Reacton backs UAE law requiring school bus fire suppression: Summary

Reacton Fire Suppression has reported that UAE regulation UAE.S 5041:2021 took effect on 15 April 2025.

The rule mandates that all school buses in the UAE be fitted with automatic fire suppression systems.

The change affects approximately 17,000 buses and up to 500,000 children.

Reacton is the first supplier approved by the Emirates Safety Laboratory to provide these systems.

Education providers are required to use an approved installer during their annual vehicle checks.

Reacton and its UAE partner TABRA have already installed over 2,500 fire suppression systems, including with Emirates Transport.

Reacton established its Dubai office in 2019 to support local operations.

TABRA has 27 years of transport safety experience in the UAE and leads the installation of Reacton systems in school and public transport fleets.

SOLBERG SPARTAN fluorine-free foam launched by Perimeter Solutions at FDIC 2025

New foam concentrate supports faster suppression and reduced water use

Perimeter Solutions has announced the release of its new SOLBERG SPARTAN 1% Fluorine-Free Class A/B Foam Concentrate at FDIC 2025 in the United States.

The company reported that the foam is designed to give firefighters more control in various fire scenarios, including structure, wildland, vehicle, gasoline, and dumpster fires.

Craig McDonnell, Vice President, Americas Fire Suppression at Perimeter Solutions, said: “SOLBERG SPARTAN is a game-changing product for firefighters.

“One foam for 99% of fires, it is our most effective fluorine-free Class A/B foam, delivering fast knockdowns, reducing flashover risk, and providing superior heat protection.”

According to Perimeter Solutions, the foam enables faster cooling times and requires less water during fire suppression activities.

Firefighters can cut cooling time and water usage

Perimeter Solutions cited data showing that cooling a fire from 1,000°F to 212°F with water alone can take nearly four minutes.

When used with water, the SOLBERG SPARTAN foam can reportedly reduce this time by more than half.

The company stated that the foam reduces water demand by 40%, helping responders to conserve resources while maintaining suppression effectiveness.

Kurt Becker, Controller, Americas Fire Suppression at Perimeter Solutions, said: “We are proud to introduce this battle-ready foam technology, providing firefighters with a solution that maximizes efficiency, conserves water, and minimizes property damage.”

Foam compatible with standard firefighting equipment

Perimeter Solutions said the product is compatible with standard firefighting systems, including inline eductors, self-inducting nozzles, monitors, medium-expansion foam devices, and compressed air foam systems.

The foam also has similar viscosity to Class A foam, making it suitable for onboard proportioning systems.

The company said this compatibility allows for easier integration into current fire service operations without requiring major changes in equipment.

Certification and environmental claims detailed

Perimeter Solutions stated that the foam carries several certifications including:

  • UL 162/ULC S654 Listed for use at 1% on Class B hydrocarbon non-water miscible fuel fires
  • UL/ULC Classified for 0.1% use on Class A fires and 0.25% on Class B non-water miscible fires
  • Classified as a Class A Wetting Agent in line with ANSI/NFPA 18

According to the company, the product contains no intentionally added PFAS.

Becker added: “As a former firefighter, I know firsthand what’s needed in the field, and today’s firefighters will be impressed by how SOLBERG SPARTAN delivers excellent performance while supporting firefighter safety.”

SOLBERG SPARTAN fluorine-free foam launched by Perimeter Solutions at FDIC 2025: Summary

Perimeter Solutions has launched its SOLBERG SPARTAN 1% Fluorine-Free Class A/B Foam Concentrate at FDIC 2025.

The foam is designed to handle structure, wildland, vehicle, gasoline, and dumpster fires.

It reduces cooling time by more than half and lowers water use by 40%.

The foam is compatible with conventional firefighting equipment.

It has similar viscosity to Class A foam and is usable in onboard proportioning systems.

Certifications include UL 162/ULC S654 for Class B fires, UL/ULC for Class A and Class B, and ANSI/NFPA 18 as a Class A Wetting Agent.

The foam contains no intentionally added PFAS.

FDIC 2025 is being held in the United States from 9 to 12 April.

NFPA highlights fire sprinkler awareness and retrofit gaps during Home Fire Sprinkler Week 2025

Campaign to promote fire sprinkler awareness returns in May 2025

The National Fire Protection Association (NFPA) has reported that Home Fire Sprinkler Week 2025 will take place from 11 to 17 May, with a renewed digital campaign aimed at informing the public about the benefits of home fire sprinklers.

According to NFPA, fire departments and safety advocates across North America will take part in the initiative through online messaging and local events.

The goal is to raise public understanding of how home fire sprinklers reduce fatalities, injuries and property loss.

The NFPA reported that home fires are responsible for over 80 percent of civilian deaths in structure fires.

Modern construction methods, synthetic furnishings and lithium-ion batteries contribute to fires that burn faster and hotter, leaving little time for escape.

Sprinkler systems offer early response and reduced damage

The NFPA has stated that home fire sprinklers can activate in less than two minutes and often control or extinguish fires before emergency responders arrive.

Only the sprinkler closest to the heat source activates, using less water than fire hoses.

The Home Fire Sprinkler Coalition (HFSC), which works in partnership with the NFPA, will lead the digital outreach.

Lorraine Carli, NFPA vice president of Outreach and Advocacy and president of HFSC, said: “Home Fire Sprinkler Week is a great opportunity for us to bring together our digital voices and amplify the message of the tremendous benefits of fire sprinklers across our continent.”

Each day of the campaign will include different themes distributed through social media and websites.

The themes include how fast fires spread, costs to communities without sprinklers and the ease of living with sprinkler systems.

Outreach and resources to support local engagement

The NFPA said that fire departments and other participants are encouraged to hold public outreach events, including live demonstrations and community displays.

Free resources will be made available through the HFSC Studio to help design educational materials.

Available tools include social media templates, flyers, videos and proclamations for use during the campaign week.

According to NFPA, the materials are designed to require minimal effort and to maximise reach through online sharing.

Visitors can find daily content and media resources on the Home Fire Sprinkler Week section of the HFSC website.

Residential high-rises in Chicago remain unsprinklered

In a related post, Lorraine Carli from NFPA commented on the continued lack of sprinklers in residential high-rise buildings in Chicago.

On 25 January 2023, a fire in the Harper Square high-rise killed one resident and displaced more than 200 others.

The building did not have a sprinkler system installed.

This fire was the first of 17 fires in unsprinklered residential high-rises in the city during 2023, Carli reported.

Ken and Rita Harris, long-time residents of the building, described the personal and financial impacts of the fire during a media briefing on its second anniversary.

They reported that over 80 residents are still waiting to return home.

Local policies have not mandated residential retrofits

Following a 2003 fire in the Cook County Administration Building that killed six people, Chicago required sprinklers in unsprinklered commercial high-rises.

However, the same requirement was not extended to residential buildings.

Carli stated that more than 600 residential high-rises in Chicago remain without sprinkler protection.

According to Harper Square residents, the cost of post-fire recovery has already exceeded $20 million.

She questioned the decision to omit residential buildings from retrofit requirements: “What is the cost of not protecting these buildings?”

Minneapolis adopted a full retrofit approach after fatal fire

In contrast, Carli pointed to the response of Minneapolis officials following a 2019 high-rise fire that killed six people.

Local, state and federal funding was used to retrofit all 42 public housing high-rises in the city.

The final retrofit was completed in August 2024.

Carli noted that sprinkler systems are often easier to install in high-rises than assumed because standpipes and fire pumps are typically already present.

Erik Hoffer, executive director of the Northern Illinois Fire Sprinkler Advisory Board, participated in the Chicago media event and supported the call for renewed attention to fire safety in high-rises.

Campaign seeks to shift public understanding and policy

The NFPA and HFSC aim to increase public awareness of the role fire sprinklers can play in both new and existing buildings.

According to Carli, modern homebuyers are more informed and are likely to favour homes with sprinkler protection once they understand the technology.

She said: “The campaign is simple and really works well. Today’s homebuyers are savvy about safety and when they learn about fire sprinklers, they want them.”

The HFSC is providing digital content, including virtual reality tools, to assist communities and advocates in communicating the benefits of sprinkler installation.

Events and outreach planned across North America

Throughout Home Fire Sprinkler Week, daily content will be distributed online and through community partners to support education about sprinklers.

Fire services across North America are expected to take part in outreach events to demonstrate how sprinkler systems operate and why they are effective.

Further information and resources are available on the HFSC website, including the daily themes and downloadable content.

NFPA highlights fire sprinkler awareness and retrofit gaps during Home Fire Sprinkler Week 2025: Summary

The National Fire Protection Association has announced that Home Fire Sprinkler Week 2025 will take place from 11 to 17 May.

The campaign, led in partnership with the Home Fire Sprinkler Coalition, promotes awareness of the role fire sprinklers play in reducing deaths, injuries and property loss in home fires.

Modern home fires burn faster and more intensely due to materials and construction methods.

Sprinkler systems activate quickly and can suppress fires using less water than hoses.

The HFSC is providing digital resources and outreach tools to support the campaign.

In a related commentary, Lorraine Carli highlighted that over 600 residential high-rises in Chicago remain without sprinkler systems.

She referenced the Harper Square fire, which killed one person in 2023, and stated that post-fire costs have already exceeded $20 million.

Chicago currently mandates sprinklers for commercial but not residential high-rises.

Minneapolis has completed retrofits for all public housing high-rises after a fatal 2019 fire.

Daily themes, educational materials and resources are available on the HFSC website.

LifeSafe launches multi-purpose extinguisher in UK with Trinity Fire & Security

Multi-purpose fluid extinguisher made available to UK market

LifeSafe has reported that its new 6-litre Multi-Purpose Fluid (MPF) extinguisher has been launched in the United Kingdom through Trinity Fire & Security.

The extinguisher has received full BSI Kitemark and CE certifications. It has also been approved for Class A, B and F fires.

Additionally, it meets the NTA 8133 standard, which tests performance against lithium-ion battery fires.

This launch follows a partnership agreement between LifeSafe and Trinity Fire & Security that began in May 2024.

Entry into global cylinder extinguisher market

LifeSafe stated that the release of the new product marks its move into the traditional fire extinguisher cylinder market.

The company has noted that this global market is estimated to be worth $9 billion annually.

Dominic Berger, Chairman of LifeSafe, said: “Our launch with Trinity Fire & Security, a hugely prestigious and respected industry leader, marks a significant milestone for LifeSafe and will provide access to a global market valued at $9 billion annually.”

Certification includes lithium-ion fire testing

The MPF extinguisher is certified to NTA 8133, which is a recognised standard for extinguishing lithium-ion battery fires.

This certification is becoming more relevant due to the increasing number of incidents involving battery-related fires.

According to LifeSafe, the new extinguisher provides coverage for multiple fire types and is designed to meet a wide range of safety needs.

Trinity Fire & Security to distribute new product

Trinity Fire & Security, established in 1997, will distribute the extinguisher through its network of ten regional offices across the UK.

The company serves more than 2,000 customers including the Ministry of Defence, NHS, and Heathrow Airport.

Richard Castle-Smith, Head of Fire Suppression at Trinity Fire & Security, said: “In the development of the MPF Fire Extinguisher alongside LifeSafe Technologies, we conducted many tests, some of which were filmed.

“They make compelling viewing, demonstrating the ease and speed with which fires are controlled and extinguished – even with a small amount of the multi purpose fluid.”

Trinity Fire & Security is part of Premier Technical Services Group (PTSG), which supports over 20,000 customers and manages more than 200,000 properties in the UK.

LifeSafe launches multi-purpose extinguisher in UK with Trinity Fire & Security: Summary

LifeSafe has announced the launch of its 6-litre Multi-Purpose Fluid extinguisher in the UK, distributed by Trinity Fire & Security.

The product is accredited with BSI Kitemark, CE, Class A, B, F and NTA 8133 certifications.

The extinguisher is intended for use against lithium-ion battery fires as well as other fire types.

LifeSafe stated this launch is part of its entry into the traditional cylinder extinguisher market, valued at $9 billion globally.

Trinity Fire & Security, a subsidiary of PTSG, will make the extinguisher available across its UK network.

LifeSafe’s Chairman Dominic Berger and Trinity’s Head of Fire Suppression Richard Castle-Smith provided comments on the launch.

CheckFire expands UK presence with acquisition of PJ Fire

Acquisition secures future of PJ Fire CO2 product line

CheckFire Group has acquired Chesterfield-based PJ Fire Ltd to strengthen its UK operations and safeguard the continued manufacture of PJ Fire’s renovated and remanufactured CO2 fire extinguishers.

According to CheckFire Group, the move supports its strategic growth across the North of England and protects PJ Fire’s established product portfolio.

PJ Fire background and legacy

Founded in 2007, PJ Fire employs 50 people and supplies fire extinguishers and ancillary products to trade customers across the UK.

Peter Cowley, founder of PJ Fire, said the acquisition marks a personal and professional milestone: “The sale of the business marks the culmination of many years of hard work, and I am delighted with this next step.

“My mission has always been to provide the highest levels of support to our valued customer base.

“CheckFire has been one of my longest-standing partnerships, and is renowned for its unmatched commitment to product excellence and exceptional customer service.

“When considering a sale, I sought honesty, integrity, and professionalism – qualities I found in CheckFire.

“Knowing that I’m passing the reins into safe hands gives me confidence that the business will continue to thrive and embark on an exciting and secure future.”

Strategic alignment with CheckFire

CheckFire’s managing director, Cameron Robins, described the acquisition as the latest development in a long-standing relationship between the two companies.

Robins said: “We are thrilled to announce the acquisition of PJ Fire, a long-term, truly strategic partner to CheckFire.

“We feel privileged to become the custodians of Mr Cowley’s legacy and reputation in the sector and delighted to have enabled his well-deserved retirement.

“This significant milestone in our partnership is allowing us to secure PJ Fire’s excellent range of products and services while leveraging CheckFire’s resources to unlock new opportunities.

“Our goals are clear: to safeguard the trading legacy of the PJ Fire brand, bolster its product offering for customers and strengthen our shared commitment to British manufacturing.

This is an exciting step forward for both businesses, and I’m really excited about the opportunities it presents for PJ Fire’s future and its dedicated team.”

Operational continuity and leadership transition

Daniel Robins, CheckFire’s director of projects, will assume leadership of PJ Fire.

Robins said the two companies share similar values and environmental commitments: “Our two businesses have a significant amount of common DNA, at our core we have deep-seated family values, and both have a passion for the environment and a sustainable approach to business.

“PJ Fire’s innovative CO2 range, including renovated and remanufactured models, is a fantastic set of products.

“I’m looking forward to working closely with the PJ Fire team in the coming months, and my focus and commitment is to maintain continuity for PJ Fire’s team and customers, and to further enhance its products and service offerings to fulfil both current and future demands.

“Clients of PJ Fire Ltd can rest assured that they will continue to receive the same level of exceptional service and support they have become reliant on over the past 18 years.”

CheckFire expands UK presence with acquisition of PJ Fire: Summary

CheckFire Group has acquired PJ Fire Ltd, based in Chesterfield, to support its northern UK operations and ensure the continued manufacture of PJ Fire’s CO2 fire extinguishers.

PJ Fire was founded in 2007 and employs 50 people.

Peter Cowley, PJ Fire’s founder, will retire following the acquisition.

Cameron Robins, managing director of CheckFire, said the acquisition would allow the business to maintain PJ Fire’s product range and support British manufacturing.

Daniel Robins, director of projects at CheckFire, will lead PJ Fire and has committed to maintaining service continuity for existing customers.

Both companies share environmental and operational values.

The acquisition supports CheckFire’s strategic plans and builds on an existing business relationship between the two firms.

Ensuring corrosion protection: How AGF Manufacturing helps facility managers extend sprinkler system life

AFG Manufacturing explores how corrosion threatens fire sprinkler systems, why standard maintenance isn’t enough and what facility managers can do to prevent system failure

Corrosion poses a significant threat in fire sprinkler systems, often remaining undetected until it’s too late.

When corrosion compromises the integrity of these systems, it can lead to leaks that result in property damage and, more alarmingly, failure during a fire event, potentially resulting in loss of life.

Despite strict adherence to Inspection, Testing and Maintenance (ITM) protocols, corrosion continues to be a persistent challenge.

Traditional ITM protocols are essential for ensuring system reliability, but they can also inadvertently accelerate corrosion rates.

This occurs because maintenance activities often involve draining and refilling the system, which introduces fresh oxygen into the pipes, fueling the corrosion process.

Fortunately, advancements in corrosion prevention strategies and technologies have provided the fire protection industry with innovative ways to combat this issue.

By integrating modern corrosion monitoring and mitigation techniques, facility managers can enhance the longevity and effectiveness of fire sprinkler systems, ultimately improving life safety outcomes.

Understanding the corrosion triangle

Corrosion in fire sprinkler systems is the result of a chemical reaction that produces rust particles.

Unlike conventional plumbing systems where continuous water flow flushes away these particles, fire sprinkler systems are typically stagnant, allowing rust and debris to accumulate over time.

This buildup can lead to obstructions within the piping network, increasing the risk of reduced water flow or complete blockages.

In a fire emergency, such obstructions could prevent sprinkler heads from effectively discharging water, thereby exacerbating property damage and endangering lives.

The corrosion triangle consists of three essential elements: steel, water and oxygen.

When all three are present, corrosion is inevitable.

Fire sprinkler systems create an ideal environment for corrosion due to the continuous presence of these elements.

While wet systems remain filled with water and oxygen, dry systems are not immune to corrosion, as they still contain trapped moisture and oxygen.

Even small amounts of residual water in a dry system can trigger significant corrosion over time.

Strategies for mitigating corrosion risks

Eliminating any component of the corrosion triangle halts the corrosion process.

While completely removing steel, water, or oxygen is impractical, effective strategies exist to minimise their interaction, significantly reducing corrosion rates.

Venting trapped air in wet systems

One of the most effective methods to mitigate corrosion in wet pipe systems that utilise metallic piping, is venting trapped air.

Studies have demonstrated that removing trapped air increases the lifespan of pipes by reducing the amount of dissolved oxygen in the water.

To address this issue, the 2016 edition of NFPA 13 introduced a requirement for air vents in wet pipe systems constructed with metallic piping.

These vents release trapped air, preventing oxygen pockets from accelerating corrosion.

Draining condensation in dry systems

Dry pipe systems are designed to be free of water until activated, but condensation often forms within the pipes.

If not properly drained, this residual water can contribute to corrosion over time.

Ensuring that dry systems are installed with appropriate piping pitch and low-point drains is essential for preventing trapped water from stagnating within the system.

Corrosion inhibitors in dry systems

In addition to proper drainage, new technologies like “Vapor Pipe Shield” by General Air Products help combat corrosion in dry systems.

This system disperses a vapor-based corrosion inhibitor throughout the piping, creating a protective barrier between the steel and any residual moisture.

The role of inspection, testing and maintenance

Routine ITM schedules are designed to detect and address performance issues before they become critical.

However, wet systems are particularly susceptible to corrosion during maintenance activities.

Each time a wet system is drained and refilled, fresh oxygen is introduced into the water, accelerating the corrosion process.

Additionally, oxygen-rich air pockets often accumulate at high points in the system, further exacerbating the problem.

Recognising this, NFPA 13 has mandated the use of air vents in wet systems to mitigate corrosion risks.

One overlooked factor in corrosion prevention is the oxygen dissolved in the water itself.

During scheduled testing, fresh water, rich in oxygen, is introduced into the system.

To counteract this, recirculation systems such as those offered by AGF Manufacturing can be used to limit the introduction of new oxygen into the system.

Not only do these systems reduce corrosion, but they also conserve thousands of gallons of water annually, aligning with sustainability initiatives and reducing unnecessary waste.

Monitoring and preventing corrosion

Implementing corrosion monitoring is crucial for identifying potential risks before they escalate.

Various monitoring methods allow facility managers to track corrosion progression accurately, providing early warnings and enabling proactive maintenance.

Powered corrosion monitoring devices

These devices provide real-time data on corrosion rates, alerting personnel to significant changes within the system.

Corrosion coupons

Corrosion coupons involve placing a metal sample inside the system, which is later analysed to determine corrosion levels over time.

While not real-time, they offer valuable insights into long-term corrosion trends.

Passive corrosion monitors

Simple and cost-effective, these monitors indicate whether corrosion is occurring within the system, enabling early intervention.

By integrating these monitoring techniques, facility managers can gain a comprehensive understanding of the corrosion conditions within their fire sprinkler systems and implement corrective actions before severe damage occurs.

Why a remote inspector’s test valve is not a good air vent

Proper air venting is essential for reducing corrosion in wet pipe fire sprinkler systems.

NFPA 13 allows for multiple venting methods, including a manual valve, an automatic air vent, or a remote inspector’s test valve.

However, using an inspector’s test valve as an air vent is ineffective.

An inspector’s test valve is designed to simulate sprinkler activation and verify system functionality, not to provide continuous air removal.

Its typical placement is for testing purposes rather than at the system’s highest point, where air naturally accumulates.

Once water fills the vertical pipe leading to the drain, air can no longer escape, leaving pockets trapped in horizontal sections.

A dedicated air vent, such as an automatic or manual vent, is a better solution.

Automatic air vents continuously release trapped air, reducing maintenance needs and corrosion risks.

Manual vents require operation but provide controlled air release.

Properly placed remote inspector’s test valves could function as vents, but their accessibility for testing may be compromised.

NFPA 13 includes remote inspector’s test valves in its list of air venting methods, but their limitations make them unsuitable for effective air removal.

To prevent corrosion, maintain system integrity, and comply with NFPA 13, fire protection professionals should prioritize dedicated air venting solutions.

Installing the right venting strategy ensures system reliability and longevity while minimizing maintenance challenges.

Taking Action Against Corrosion

Effective corrosion management requires a proactive approach.

The integration of air vents, recirculation systems, corrosion inhibitors and monitoring devices significantly reduces corrosion risks and extends the lifespan of fire sprinkler systems.

Additionally, partnering with trusted manufacturers like AGF Manufacturing ensures access to high-quality corrosion prevention products tailored to the specific needs of fire protection systems in various environments.

From automatic air venting valves to innovative recirculation solutions, AGF offers a comprehensive range of products designed to enhance system longevity, reliability, and overall performance.

To safeguard lives and property, facility managers, fire protection engineers and building owners must remain vigilant against corrosion threats.

By implementing best practices in corrosion prevention and leveraging advanced technologies, they can ensure that fire sprinkler systems remain operational and effective when needed most.

For more information on corrosion prevention products or to find a distributor, please visit www.agfmfg.com

This article was originally published in the April 2025 issue of International Fire & Safety Journal – to read your FREE digital copy, click here.