CROSS UK examines Glasgow Union Street fire lessons

Glasgow fire and historic building risk

A CROSS UK feature article reflects on the Glasgow Union Street fire on 8 March 2026 and sets out the fire safety issues that can affect older and listed buildings.

The article says the cause of the fire at the B-listed building on Union Street has not yet been determined and that investigations are ongoing.

Emergency services responded quickly and no injuries were reported. The fire destroyed the businesses within the building.

Damage to the structure also disrupted nearby businesses and transport infrastructure.

CROSS UK says incidents of this kind show how fires in historic buildings can affect city centres and local economies even when there are no casualties.

Glasgow lessons from older construction and change of use

Older and larger historic buildings often contain timber floor structures, lath and plaster walls and ceilings, cast iron frames and columns, along with hidden voids and complex roof spaces.

These features can affect how fire starts and spreads.

Timber floors, concealed cavities and linked roof spaces can allow fire and smoke to move through a building without being seen.

The article says many historic buildings also lack a clear documented fire strategy.

Original drawings may be incomplete or unavailable.

A building may also have changed use several times across its life, altering layouts, occupancy patterns and fire loading.

Service penetrations for ductwork, cables and pipework can also create routes for fire spread where openings are not properly fire stopped.

Managing fire safety in heritage buildings

CROSS UK says effective management in heritage buildings starts with a competent fire risk assessment that reflects the building’s construction, layout and current use.

The article says this work may require a fire risk assessor with experience of heritage buildings, especially where concealed spaces or older construction systems are involved.

It also calls for a formal fire strategy that addresses life safety and property protection.

That strategy should cover detection, compartmentation, suppression and management.

In leased buildings, leaseholders and landlords may each hold responsibilities for fire safety measures in different parts of the premises.

The article says coordination between responsible persons is needed so that fire risk assessments and fire strategies align across the whole building.

It also points to early detection, maintenance, housekeeping, control of contractors and hot work, protection of compartmentation and control of fire loads and ignition sources as parts of fire safety management in older buildings.

The article ends by stating that fires in historic buildings can leave lasting economic and cultural damage, and that protecting them depends on a proactive and coordinated fire safety approach.

Read the CROSS UK article here.

Gold Innovation award recognises Chester Rows fire detection project

Innovation award recognises Chester Rows fire detection project

Cheshire Fire and Rescue Service and Cheshire West and Chester Council have won Gold in the Innovation in Public Sector Award at the IESE Public Sector Transformation Awards in Westminster for a fire protection system installed on Chester’s historic Rows.

Cheshire Fire and Rescue Service reported that the project installed an aspirating smoke detection system across the outdoor heritage site, marking the first use of this type of early warning technology at an outdoor historic site in the UK.

The work involved collaboration between the council, heritage specialists and the Protection Department at Cheshire Fire and Rescue Service.

In January, the system detected smoke from a fire at a commercial premises on Music Hall Passage more than 100 metres away.

The blaze had also been reported through a 999 call.

The early alert demonstrated how the system could provide warning if a fire occurred at night, when the Rows are more exposed.

Project partners and national recognition

The installation was carried out with Charles Thomas Heritage Fire Protection Specialists, Donald Insall Associates, Recclesia and specialist consultants, with part funding from the UK Shared Prosperity Fund.

Steve McCormick, Head of Prevention and Protection at Cheshire Fire and Rescue Service, said: “We are incredibly proud to see this innovative project recognised on a national stage.

“The system installed on the Rows brings together cutting edge technology and expert heritage protection, providing a level of early warning fire detection never before achieved on a historic site like this.

“This award is a testament to the dedication of all partners involved, including our Technical Fire Safety Heritage Officer, James Scott, whose work has been fundamental to the project’s success.”

Councillor Louise Gittins, Leader of Cheshire West and Chester Council, said: “I’m delighted that the introduction of our Aspirating Smoke Detection system is not only helping to protect the Chester Rows, but the technology and innovation could play a part in protecting many more heritage sites across the country.

“The new system plays a vital role in our fire protection action plan.

“Winning this gold award will help to showcase the system to far more sites. Congratulations to the many people involved in developing, installing and running the new system.”

The system is now being considered by councils and conservation bodies as a possible approach for heritage fire protection at other sites.